Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
16 Appendix Device Configuration
74
Order number 2354913 | Edition 10/2022
6. To exit the configuration, switch control unit to standby mode by pressing the
[Standby] button (15). Pressing this button again returns the control unit to normal
operating mode.
16.3 TABLE OF PARAMETERS
Parameter
Value
Description
C11
Gun charging type
cor
(factory setting)
WAGNER Corona spray guns can be con-
nected to the unit; a Tribo gun will trigger
a fault.
tri
WAGNER Tribo guns can be connected to
the unit; a Corona gun will not trigger a
fault.
aut
Tribo or Corona spray guns can be con-
nected to the unit. The system only
changes to the correct type after it is first
switched on with the gun's trigger or the
master controller.
C12
Selection reset function
OFF
The selection function is switched off. A
selection is retained until another selec-
tion is made.
ON
(factory setting)
Selection function is switched on: after 5
seconds, the selection automatically re-
turns to the powder quantity setting.
C13
Lock
OFF
(factory setting)
Lock is deactivated.
ON
Lock is activated, values cannot be
changed, user can only select recipes and
control functions.
Recipe values cannot be changed.
Pro
Lock sometimes activated.
Recipe storage is blocked, otherwise func-
tion as in the [OFF] position. Values can be
changed temporarily.
C14
[Double-click] function
OFF
[Double-click] function is deactivated.
ON
(factory setting)
The [Double-click] function is activated.
When the manual gun's trigger is pressed
twice to switch on, the program jumps to
the [Double-click] recipe; at the next
switch-on the previous recipe is selected
again.
C15
Operating hours counter
only display
The actual coating hours are counted. The
numerical value displayed should be mul-
tiplied by 100.
Examples:
0.15 -> 0.15 * 100 h = 15 operating hours
050 -> 50 * 100 h = 5000 operating hours