Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
7 Operation
48
Order number 2354913 | Edition 10/2022
7.7.4 Procedure for Cleaning Flushing with Automatic Guns
P_01759
EPG
SPRINT X
0
%
10
20
30
40
50
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
80
100
%
Tri
90
60
70
35
34
18
15
17
1. End coating operation.
2. Remove powder suction unit (suction lance, powder injector) from powder tank.
3. Switch on flushing function by pressing [Flushing] button (17) on the control unit.
ð
LED display (18) starts to flash and indicates readiness for flushing.
4. Process should be repeated for each spray gun that is to be flushed.
5. If you do not want a flushing process, press [Standby] button (15).
6. Start flushing process using [Gun start] on the system controller.
7. Stop flushing process using [Gun Stop] on the system controller.
8. Re-activate control units in standby mode by pressing the [Standby] button (15).
9. Press [Flushing] button (17) to return to normal coating mode.
ð
The LED display (18) no longer flashes.
10. Once the suction lance has been lowered into the powder tank, the coating operation
can be continued again.
Info
If configuration parameter C16 is set to [ON], the flushing function can only be activated
via the serial interface.
7.8 STARTING OUTPUT SETTING (ZERO ADJUSTMENT)
This function can be used to set the point from which powder is fed. The starting output
setting is subject to:
– The diameter of the powder hose
– The length of the powder hose
– The feed properties of the powder