Operating manual Universal Control Unit for Powder Spray Guns EPG-SPRINT XE
7 Operation
Order number 2354913 | Edition 10/2022
43
EPG
SPRINT X
0
%
100
%
kV
80
60
40
20
100
Tri
Cor
5
4
3
2
1
120
80
40
20
10
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
µA
P_01754
19
24
1
2. The high voltage can now be set using the universal control dial (24) between 10 –
100 kV with a resolution of 1 kV. The value is shown in the LED display (19).
Above the [High voltage] push button (27) is the [High-voltage] bar graph display (1). When
the control unit is in the ready position, this light strip shows the set point as a dot and,
when high voltage is switched on, it shows the actual value as a bar.
The high voltage can be set between 10 – 100 kV as described above. If this value is further
reduced from a value of 10 kV, the word [off] appears in the LED display (19) to signal that
the high voltage is deactivated. The high-voltage generation is not therefore activated when
the powder feed is switched on.
7.6.5 Displaying Actual High-voltage Value
The actual high-voltage value can be displayed during the coating process in LED display
(19).
EPG
SPRINT X
0
%
100
%
kV
80
60
40
20
100
Tri
Cor
5
4
3
2
1
120
80
40
20
10
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
µA
P_01755
28
27
19
24
4
Press [High-voltage] push button (27) for around 2 seconds. Yellow LED (28) flashes
quickly. The actual high-voltage value is shown in the LED display (19) for 5 seconds,
the display returns to the previous display after this time. The actual value display can
also be interrupted before expiration of the 5 seconds by pressing a selection button or
turning the universal control dial (24).