11
VAS 581 001A
Safety
2.5
Warnings on the AirConServiceCenter
Please note!
Observe the operating manual!
Only connect the device to a socket with 230 V/50 Hz AC.
Protect the device against rain.
Wear gloves when handling refrigerants.
Wear goggles when handling refrigerants.
Trained personnel!
2.6
Safety devices
Pressure monitor: switches the compressor off if the normal operating
pressure is exceeded.
Pressure relief valves: additional safety mechanism to protect lines or
vessels from bursting if the pressure continues to rise despite the
action of the pressure monitor.
Fan and electronic box (delay circuit): checks the fans work properly
at start-up.
Door opener contact prevents the front panel and dryer cover from
opening while operating.
VAS-581-001A--O-US.book Seite 11 Montag, 17. Februar 2020 8:25 20