![Wacker Neuson WP 1540A Operator'S Manual Download Page 21](http://html1.mh-extra.com/html/wacker-neuson/wp-1540a/wp-1540a_operators-manual_3366670021.webp)
WP 1540A/AW
Operation
wpm_tx001129gb.fm
19
4.3
To Start
See Graphic: wc_gr000014
4.3.1
Open fuel valve by moving lever to the right
(a1)
.
Note
:
If engine is cold, move choke lever to close position
(b1)
. If
engine is hot, set choke to open position
(b2)
.
4.3.2
Turn engine switch to “ON”
(e1)
.
4.3.3
Open throttle by moving it slightly to left
(d1)
.
4.3.4
Pull starter rope
(c)
.
Note
:
If the oil level in the engine is low, the engine will not start. If this
happens, add oil to engine. Some engines are equipped with an oil
alert light
(f)
that will come on while pulling the starter rope.
4.3.5
Open choke as engine warms
(b2)
.
4.3.6
Open throttle fully to operate.
4.4
To Stop
See Graphic: wc_gr000014
4.4.1
Reduce engine RPM to idle by moving throttle completely to right
(d2)
.
4.4.2
Turn engine switch to “OFF”
(e2)
.
4.4.3
Close fuel valve by moving lever to the left
(a2)
.
Summary of Contents for WP 1540A
Page 1: ...Operator s Manual Vibroplate WP 1540A WP 1540AW 5000190153 16 0811...