10 Operation
100_0101_op_0011.fm
27
10.3
Decommissioning
Switch off the unit
1. Slowly pull the vibrator head out of the freshly mixed (green) concrete and hold it in the air.
2. Switch the equipment off with the ON/OFF switch.
3. Wait until the equipment has come to a complete standstill.
4. Slowly stop the equipment (operative position) and set down the corresponding flexible shaft and
vibrator head.
5. Pull the plug out of the plug receptacle.
6. Allow the equipment to cool down.
Disconnect the flexible shaft from the drive motor
1. Pull the t-handle.
2. Pull the coupling of the flexible shaft out of the quick disconnect coupling of the drive system.
3. Release the t-handle.
4. Safely place the equipment down on level and stable surface so that the drive motor cannot tip over,
fall over or slip away.
Clean equipment
Clean all components of the HMS after every application.
1. Clean the vibrator head and flexible shaft with water.
2. Wipe down the drive motor and flexible shaft with a damp clean cloth.
3. Clean the ventilation slots with an appropriate, non-metallic auxiliary tool.
CAUTION
Proper motion of the running vibrator head outside of the freshly mixed (green) concrete.
Risk of injury or danger of property damage due to beating around vibrator head.
Switch the equipment off before setting it down.
CAUTION
Warming up the running vibrator head outside of the freshly mixed (green) concrete.
Risk of burning from hot surface.
Damage to the equipment from increased wear.
Do not run the equipment outside of the freshly mixed (green) concrete.
NOTICE
Do not bend the protection hose and power cable.
CAUTION
Risk of burning from hot coupling of the flexible shaft.
Only touch the coupling with protective gloves.
NOTICE
With the equipment running, you can remove the concrete residue from the vibrator head
by immersing it in a gravel bed.