Electrical Testing Techniques
Mobile Generator
22
wc_tx000699gb.fm
3
Electrical Testing Techniques
3.1
Checking Continuity
Conduct continuity tests when the engine is shut down.
When checking continuity, use the Ohm setting on your multimeter.
Place a lead of the multimeter on one end of the wiring or component
and the other lead on the opposite end. If your meter reads “OL” or
“OPEN”, there is no continuity and the wiring or component must be
repaired or replaced.
Note: Some multimeters also have an audio signal setting for
determining continuity. This setting may also be used.
•
If your meter reads less than 1.0 Ohm, or the audio signal
sounds, the wiring or component has continuity and should be
OK.
•
If your meter reads more than 1.0 Ohm, the wiring is faulty and
must be repaired or replaced.
3.2
Checking Resistance
Conduct resistance checks when the engine is shut down.
Use the Ohm setting on your multimeter.
Conduct resistance checks when the machine is as close to 21°C
(70°F) as possible. Higher temperatures can affect resistance values.
Most digital multimeters have some internal resistance. To obtain your
multimeter’s internal resistance, simply cross the two leads of your
multimeter and read the display. When conducting a resistance check,
subtract your multimeter’s internal resistance from the value you
measure to obtain the true resistance of the component you are
checking.
3.3
Checking Voltage
Conduct voltage checks when the engine is running.
Use the Volt setting on your multimeter. To prevent damage to your
instrument, start with the highest scale available on your multimeter.
Adjust to a lower scale as readings dictate.
Use extreme caution when checking voltage to reduce the risk of
electric shock.
Summary of Contents for G 85
Page 1: ...Repair Manual Mobile Generator G 85 0171726en 004 0809 0 1 7 1 7 2 6 E N ...
Page 8: ...Table of Contents MG Repair wc_br0171726en_004TOC fm 8 ...
Page 17: ...Mobile Generator Theory of Operation wc_tx001077gb fm 17 wc_gr003303 c a a d e f b c b d e ...
Page 58: ...ECM Sensor Troubleshooting Mobile Generator wc_tx000723gb fm 58 Notes ...
Page 85: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 85 c h b d d e f g a wc_gr003320 a ...
Page 87: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 87 wc_gr003321 a f e j i h b c d g ...
Page 95: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 95 Notes ...
Page 97: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 97 wc_gr003351 a c c e g b d f ...
Page 99: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 99 wc_gr003352 a c c e g b d f ...
Page 101: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 101 a c b b wc_gr003350 ...
Page 103: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 103 wc_gr003286 a b c ...
Page 105: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 105 ...
Page 109: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 109 wc_gr003284 b a c d e ...
Page 111: ...Mobile Generator Disassembly Assembly wc_tx000575gb fm 111 Notes ...