BA ET16 de* 1.0 * et16b510.fm
5-55
Operation 5
5.14 Putting out of operation/back into operation
The specified measures refer to putting the machine out of operation and
back into operation after more than 30 days.
Putting out of operation temporarily
Store the machine indoors if possible.
If the machine has to be stored outdoors, place it on firm ground if
possible (for example on concrete), and cover it with a watertight tarp to
protect it against humidity.
1. Park the machine
– see “Parking the machine” on page 5-8
2. Clean the engine with a high-pressure cleaner in a suitable place
see chapter “7.5 Cleaning and maintenance” on page 7-21
3. Check the machine for leaks and loose nuts, screws and connections.
4. Carefully clean and dry the entire machine.
5. Spray an anticorrosion agent onto bare metal parts of the machine
(piston rods of hydraulic cylinders, for example).
6. Apply grease to all lubrication points.
7. Fill the fuel tank completely.
8. Check the hydraulic oil and coolant levels, and add hydraulic oil and
coolant if necessary.
9. Change engine oil.
10.Remove the battery and store it in a safe place. Charge the battery and
perform battery maintenance at regular intervals.
11.Set the fuel cock to
OFF
.
12.Close the air-intake openings of the air filter system and exhaust pipe.
Summary of Contents for ET09-02
Page 6: ...EG 2 BA ET16 de 1 0 et16konf fm Declaration of conformity Notes...
Page 36: ...2 22 BA ET16 de 1 0 Safety_01_0 fm 2 Safety Notes...
Page 45: ...BA ET16 de 1 0 et16e300 fm 3 9 Introduction 3 Warning labels...
Page 49: ...BA ET16 de 1 0 et16e300 fm 3 13 Introduction 3 Labels...
Page 54: ...3 18 BA ET16 de 1 0 et16e300 fm 3 Introduction ANSI label option...
Page 102: ...4 42 BA ET16 de 1 0 et16i400 fm 4 Putting into operation Notes...
Page 160: ...5 58 BA ET16 de 1 0 et16b510 fm 5 Operation Notes...
Page 218: ...8 4 BA ET16 de 1 0 et16b800 fm 8 Malfunctions Notes...
Page 242: ...9 24 BA ET16 de 1 0 et16t900 fm 9 Technical data Notes...