![Wacker Neuson 0008060 Operator'S Manual Download Page 32](http://html1.mh-extra.com/html/wacker-neuson/0008060/0008060_operators-manual_866546032.webp)
Maintenance
WP 1540A/AW
wpm_tx001130gb.fm
30
5.9
Cleaning Sediment Cup
See Graphic: wc_gr000029
5.9.1
Turn the fuel valve off.
5.9.2
Remove the sediment cup
(a)
and the O-ring
(b)
.
5.9.3
Wash both thoroughly in a nonflammable solvent. Dry and reinstall
them.
5.9.4
Turn the fuel valve on and check for leaks.
5.10 Adjusting Engine Speed
See Graphic: wc_gr000280
Adjust to a full load speed of 3600 ± 100 rpm.
To adjust engine speed:
5.10.1 Place machine on a rubber test mat to prevent it from moving.
5.10.2 Start engine and allow it to warm up for a minute.
5.10.3 Turn throttle stop screw
(a)
in to increase speed, out to decrease
speed. Make sure throttle lever is touching stop screw before
measuring RPM.
NOTICE
:
Running plate at a speed higher than that listed in
Technical
Data
can damage both the plate and the engine.
wc_gr000280