4.12 Carburetor Adjustment—Machines with Honda Engines
See Graphic: wc_gr000032
4.12.1
Start the engine and allow it to warm up to operating temperature.
4.12.2
Set the pilot screw
(a)
two turns out. See
Note.
4.12.3
With the engine idling, turn the pilot screw
(a)
in or out to the setting
that produces the highest rpm.
4.12.4
After the pilot screw is adjusted, turn the throttle stop screw
(b)
to
obtain the standard idle speed. See
Technical Data.
Note:
On some engines the pilot screw is fitted with a limiter cap
(c)
to prevent excessive enrichment of the air-fuel mixture in order to
comply with emission regulations. The mixture is set at the factory and
no adjustment should be necessary. Do not attempt to remove the
limiter cap. The limiter cap cannot be removed without breaking the
pilot screw.
4.13 Adjusting Idle Speed—Machines with Honda Engines
See Graphic: wc_gr000032
To adjust idle speed:
4.13.1
Start engine and allow it to warm up to normal operating temperature.
4.13.2
Turn throttle stop screw
(b)
in to increase speed, out to decrease
speed.
Summary of Contents for 0007659
Page 2: ......
Page 11: ...PG Pumps Safety Information wc_si000180gb fm 7 1 4 Label Locations w c _ g r 0 0 0 8 3 3...
Page 39: ...PG Repair Disassembly Assembly Procedures wc_tx000608gb fm 35 4 9 10 2 3 1 6 5 7 wc_gr003495 8...
Page 47: ...PG Repair Disassembly Assembly Procedures wc_tx000608gb fm 43 8 11 12 9 7 10 6 5 wc_gr003499...
Page 53: ...PG Repair Disassembly Assembly Procedures wc_tx000608gb fm 49 1 wc_gr003501...
Page 54: ...Disassembly Assembly Procedures PG Repair wc_tx000608gb fm 50...
Page 59: ......