4.3.4.33
6505h
– Warnings
Object 6505h outputs the status of the supported warnings.
Signal
6505h
– Warnings
Bit
15 … 9
8
7
6
5
4
3
2
1
0
Contents
15 … 9
Not used
Always 0
8
Jerk range
always 0, since object 6050h is not supported
7
Acceleration range
always 0, since object 6040h is not supported
6
Speed range
Is set if the value range of object 6030h is insufficient to
represent the speed.
5
Reference point
Always 0
4
Battery charge
always 0, since no battery is being used
3
Operating time limit
Always 0
2
CPU watchdog status
always 0, not supported
1
Light control
Always 0, not optical, but rather magnetic sensors
0
Frequency exceeded
Is set if the speed defined in object 2107h is exceeded. Is
deleted as soon as the speed falls below this limit again.
Table 4.35: Signal description
4.3.4.34
6506h
– Supported warnings
Object 6506h shows the supported warnings. Frequency exceeded and Speed range
are supported, therefore always 0x0041h.
4.3.4.35
6507h
– Profile and software version
Object 6507h specifies the software version and profile.
Byte
Meaning
Example
4 (MSB)
Profile Version Major
04h
00h = Version 04.00
3
Profile Version Minor
2
Software Version Major
01h
40h = Version 01.64
1
Software Version Minor
Table 4.36: Example of profile software version
Summary of Contents for WDGA 58A