![WABCO LEAKAGE FINDER 2.0 Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/wabco/leakage-finder-2-0/leakage-finder-2-0_operating-instructions-manual_3107875013.webp)
13
Product description
EN
6.1.4
Start-up
NOTICE
Damage to the WABCO Leakage Finder 2.0
The WABCO Leakage Finder 2.0 may be damaged if operated with power sources that are not within
the specified operating voltage range.
–
Only operate the WABCO Leakage Finder 2.0 with power sources that are within the specified
operating voltage range
Chapter "4 Technical data", page 7.
Insert batteries
i
i
Matching rechargeable batteries can also be used to operate the WABCO Leakage Finders
2.0. The charge level for rechargeable batteries is displayed approximately.
– Unscrew and remove the battery compartment cover.
NOTICE
Damage to the WABCO Leakage Finder 2.0
Inserting the batteries incorrectly into the battery compartment can damage the WABCO Leakage
Finder 2.0.
–
Place the batteries (2 AA 1.5 V) in the battery compartment as shown on the bottom of the unit.
– Close the battery compartment again by fastening the cover.
Ö
When the device is in operation, the charge status of the batteries is shown on the display.
Switch the device on/off
– Press
to switch the device on.
Ö
During start-up, the device displays the current software version for a few seconds.
Ö
The unit then displays the current sound pressure level and is ready for operation.
– Press
again to switch the device off.
Adjust volume
– Press
to increase the volume, press
to reduce the volume.
Ö
The current volume level is indicated on the display.
The hearing volume can be varied between -42 dB and 0 dB in steps of 2 dB. When switching on, the
setting is always -22 dB.
Switch maximum level detection on/off
– Press
to switch the maximum level detection on.
Ö
The value (MAX XX.X) is shown at the bottom left of the display.
– Press
again to switch the maximum level detection off.
Ö
The value (MAX XX.X) disappears again.