4 Technical description
4.2 Input and output signals
Connection
Supply
PIN 3
Power supply (see technical data).
PIN 4
0 V (GND) connection.
Connection
Analogue signals
PIN 9 / 10
Q-value (QA), signal range ± 10V or
4…12…20 mA, scalable (SIGNAL:Q / AIN Q).
PIN 6
p-command value (WA), signal range
0…10V or 4… 20mA, scalable (SIGNAL:W / AIN W).
PIN 13
Pressure (force) feedback value (XA
1), 0… 10 V or 4… 20 mA (SIGNAL:X1 / AIN X1).
PIN 14
Pressure (force) feedback
value (XA2), 0… 10 V or 4… 20 mA (SIGNAL:X2 / AIN X2).
PIN 11
0 V (GND) connection for analogue input signals.
PIN 12
0 V (GND) connection for analogue output signals.
PIN 15 / 16
PIN 15 / 12
Valve control signal.
Type of signal and polarity can be selected by the parameter SIGNAL:U.
Connection
Digital inputs and outputs
PIN 8
Enable input:
General enabling of the application.!
PIN 7
RUN:
ON:
The controller is activated.
OFF:
Controller deactivated
.
The Q-value (PIN9/10) is placed on the output.
PIN 5
RAMP/PSET:
Ramp for the pressure setpoint is activated. Alternatively can be switched over to a second
set of parameters for the PID controller depending on PIN 5 parameter.
PIN 1
READY output:
ON
:
The module is enabled; there are no discernable errors.
OFF:
Enable (PIN 8) is deactivated or a failure (current input or intern) has been detected
(depending on the SENS command).
PIN 2
STATUS output (error monitoring):
ON:
The axis is within the pre-set monitoring range.
OFF:
The axis is without the pre-set monitoring range.