27
6.3
Product State Machine
Power Off: product have not any power
Power On: power up and initialize drivers and system
Broadcast: broadcast IP address, socket do not connect
Connected: socket connected, product can transfer image and answer host
command
Upgrade: product upgrade the firmware mode
6.4
Software Command Set
DCAM800 support different work mode like depth_30, IR_30, depth&IR_30.
Three default range: range0(0.35m~1.5m), range2(0.8m~4.4m), range5(1.2m~6.2m).
User can use UTool to try the different command or can use the APIs to control the
camera. The details please reference the SDK documents.
6.5
IP Address Configuration
You can connect the camera to the host via either direct connection or DHCP
connection.