BASKET LIFT CAM SWITCH
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
2.
Disconnect lead wires from cam switch.
3.
Remove screws securing cam switch to cam
bracket.
Fig. 34
4.
Reverse procedure to install.
BASKET LIFT CAM
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
2.
Remove nut securing lift bar to cam assembly.
3.
Loosen cam set screw.
4.
Remove screws securing cam to the crank arm
assembly.
Fig. 35
5.
Reverse procedure to install.
FILL SOLENOID VALVE (KSP)
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
1.
Remove filter tank from fryer.
2.
Access fill solenoid valve.
3.
Loosen union at rear of valve,
4.
Remove bolts securing valve and remove valve
from the fryer.
VK and TR GAS FRYERS W/Wo KleenScreen PLUS - REMOVAL AND REPLACEMENT OF PARTS
Page 19 of 55
F45474 (0413)