V SERIES PROOFING CABINET
F-41190 (02-16)
5
ELECTRICAL REQUIREMENTS
ELECTRICAL CODES & STANDARDS:
The cabinet must be installed in
accordance with:
In the United States of America:
1.
State and Local Codes.
2.
National Electrical Code, ANSI/
NFPA-70 (latest edition.) Copies
may be obtained from: The
National Fire Protection
Association, 1Batterymarch Park,
Quincy, MA 02269.
1-617-770-3000
www.nfpa.org
In Canada:
1. Local
Codes.
2.
Canadian Electrical Code, CSA
C22.1 (latest edition.) Copies
may be obtained from: The
Canadian
Standard
Association.
www.csa.ca
ELECTRICAL CONNECTIONS:
The cabinet is factory wired for either
110/120 volt or 208/240 volt, single
phase operation. All 110/120 volt
cabinets are equipped with a 8 foot cord
and NEMA 5-20 plug as standard
equipment. All 208/240 volt cabinets
are equipped with an 8 foot cord and
NEMA 6-15 plug. Refer to wiring
diagram in the back of this manual.
The cord and plug supplied is a suitable
durable cord with a molded three-prong
plug, and is provided with a proper
strain relief.
All cabinets are
equipped with a three-prong plug. It
is imperative that this plug must be
connected into a properly grounded
three-prong receptacle. If the
receptacle is not the proper
grounding type, contact an
electrician. Do not remove the
grounding prong from this plug.
Verify that the power source
matches the Serial Data Plate located
on the lower back corner of the
cabinet and the plug configuration
before the connection is made.
(Fig.4)
(Fig. 4)