25
9. Pull the limit bulb out from underneath the fryer tank. (See Fig. 86)
10. Reinstall new high limit by reversing steps 1-9.
REMOVAL OF THERMOPILE (STANDARD MILLIVOLT SYSTEM)
1.
Follow steps 1- 3 under Control Panel (Standard Millivolt Construction)
2.
With a 1/4" socket disengage (4) #8 hex head screws, pull the thermostat wire from the housing and remove
the control housing. (Figs. 27)
Fig. 28
Figs. 27
3.
From the high limit disengage the closed and normally open thermopile wire leads. (Fig. 28)