ELECTRIC COMBI OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
Page 25 of 68
NOTE: The temperature selected in the table below
will also be the highest starting point temperature
available, when the steam mode is selected.
ELEVATION
(FT)
TEMPERATURE
(°F)
Sea level to 500
212
500 to 1000
211
1,000 to 2,000
209
2,000 to 3,000
207
3,000 to 4,000
205
4,000 to 5,000
204
5,000 to 6,000
202
6,000 to 7,000
200
7,000 to 8,000
198
8,000 to 9,000
196
9,000 to 10,000
195
Above 10,000
194
8.
CCC is displayed in the time display and the
convection temperature limit is displayed in the
temperature display. Press the TEMP UP key
to increase number (482°F to 518°F) and
TEMP DOWN key to decrease number. Set the
temperature to read 518°F. Press the
START/STOP key to advance to the next step.
9.
1 - - is displayed in the time display and the
minimum value for the convection fan motor is
displayed in the temperature display. Press the
TEMP UP key to increase number and TEMP
DOWN key to decrease number. Set according
to Position 1 (minimum) in the table below. If
the value is correct, press the START/STOP
key to advance to the next step.
10. 2 - - is displayed in the time display and a
maximum value for the convection fan motor is
displayed in the temperature display. Press the
TEMP UP key to increase number and the
TEMP DOWN key to decrease number. Set
according to Position 2 (maximum) in the table
below. If the value is correct, press the
START/STOP key to advance to the next step.
CONVECTION FAN
MOTOR TYPE
CONVECTION FAN MOTOR
VALUE
POSITION 1
(MINIMUM)
POSITION 2
(MAXIMUM)
1 motor Leroy-Somer
(Hanning)
8
55
1 motor Brook-Crompton *
8
60
2 motors Leroy-Somer
(Hanning)
46
120
2 motors Brook-Crompton
30
90
1 motor Leroy-Somer
(Hanning) and 1 motor
Brook-Crompton
38
105
NOTE:
(*) Ovens are shipped from the factory with this
motor and the oven control is configured
accordingly.
The values correspond to the current limits only
and are not the actual current draw of the motor.
11. If all the values have been entered correctly,
press the OFF key to save the configuration
settings and exit the configuration mode. To
review or change a configuration value press
the START/STOP key to return to step 1.
DIAGNOSTIC TEST MODE -
PROGRAMABLE CONTROL
The test mode can be entered only when the oven is
OFF. The five tests are run in sequence (1 - 5) and
are indicated by the position of the illuminated LED
in the bar graph of the combi mode key.
The test are performed in a fixed sequence of:
1.
ROM (automatically)
2.
RAM (automatically)
3.
Displays and LED’s
4.
Relays (relay on for max. of 2 seconds)
5.
Keypad
To Perform:
1.
To enter the test mode press the TEMP, TEMP
UP and TEMP DOWN keys simultaneously for
3 seconds. The word “test” will be displayed in
the temperature display.
2.
If a ROM or RAM error is detected, a error
code (01 = ROM and 02 = RAM) will be
displayed on the temperature display and will
repeat until a key is pushed to exit this test. If
no errors are detected, the control advances to
the next test and runs it automatically.
Summary of Contents for 126172
Page 40: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 40 of 68 COMPONENT LOCATION ...
Page 41: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 41 of 68 ...
Page 54: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 54 of 68 WIRING DIAGRAMS 6 Level ...
Page 55: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 55 of 68 ...
Page 56: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 56 of 68 10 Level ...
Page 57: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 57 of 68 ...
Page 58: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 58 of 68 20 Level ...
Page 59: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 59 of 68 ...
Page 60: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 60 of 68 ELECTRIC HEATER CIRCUITS ...
Page 61: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 61 of 68 ...
Page 62: ...ELECTRIC COMBI OVEN ELECTRICAL OPERATION Page 62 of 68 ...