Vulcan-Hart 024C ML-103833 Service & Parts Manual Download Page 1

– 1 –

1024, 1036, 1048 CHEESEMELTER

MODELS

1024C

ML-103833

1024W

ML-103834

1024P

ML-103835

1036C

ML-103836

1036W

ML-103837

1036P

ML-103838

1048C

ML-103839

1048W

ML-103840

1048P

ML-103841

SERVICE &

PARTS MANUAL

FORM 31087 Rev. B (June 2006)

Model 1036W

For additional information on Vulcan-Hart or to locate an authorized parts

and service provider in your area, visit our website at www.vulcanhart.com

VULCAN-HART
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANHART.COM

P.O. BOX 696, LOUISVILLE, KY 40201-0696

TEL. (800) 814-2028

Summary of Contents for 024C ML-103833

Page 1: ...L 103840 1048P ML 103841 SERVICE PARTS MANUAL FORM 31087 Rev B June 2006 Model 1036W For additional information on Vulcan Hart or to locate an authorized parts and service provider in your area visit our website at www vulcanhart com VULCAN HART DIVISION OF ITW FOOD EQUIPMENT GROUP LLC WWW VULCANHART COM P O BOX 696 LOUISVILLE KY 40201 0696 TEL 800 814 2028 ...

Page 2: ... seated correctly COOLING FANS 1 Remove the access panel on the left side of the cheesemelter 2 Unscrew the four mounting screws 3 Disconnect the fan leads and lift out the fan 4 Install new fan Make sure that all wires are enclosed by the nylon wire clamps so that none of the wires can reach the fan blades The cooling fan should blow air into the control compartment An arrow on the fan housing in...

Page 3: ... plate 1 Disconnect the wires from the on pilot light and the switches 2 Tag or mark the wires to ensure correct replacement 3 Remove the two mounting screws One is located at the bottom left of the voltage regulator The other is located under the lower part of the cooling fan This screw can be reached through the blades of the fan 4 Remove the component mounting plate and replace the component Ma...

Page 4: ...DRAWING COMPONENT LOCATION VIEW OF LEFT SIDE WITH COVER REMOVED PL 53527 SOCKETS CONTACTOR 1048 PILOT LIGHT ACTUATING SWITCH COOLING FAN NYLON LOOP TERMINAL BLOCK GROUND STUD VOLTAGE REGULATOR SWITCH COMPONENT MOUNTING PLATE ...

Page 5: ...ating in standby with no product on the rack the heaters may not glow but will still emit some heat 6 If one heater is lit but the other is not a burnout or a loose connection is the probable cause Also check that the heater is properly seated in its socket IF THE COOLING FAN DOES NOT RUN 1 If the pilot light is not lit and the heaters do not light check for a blown fuse or open circuit breaker 2 ...

Page 6: ... 6 ELECTRICAL SCHEMATIC 1024 1036 PL 53528 HEATERS VOLTAGE REGULATOR ACTUATING SWITCH MAIN SWITCH LIGHT PILOT FAN GROUND LUG TERMINAL BLOCK ...

Page 7: ...48 PL 53529 LEFT SIDE HEATERS RIGHT SIDE HEATERS VOLTAGE REGULATOR RIGHT SWITCH LEFT SWITCH RIGHT PILOT LIGHT LEFT PILOT LIGHT FAN LIGHT MAIN PILOT GROUND STUD CONTACTOR MAIN SWITCH TERMINAL BLOCK 1048 SCHEMATIC ACTUATING SWITCH ...

Page 8: ...over Mounting Screws SC 066 21 SC 066 21 SC 066 20 16 Heat Shield Deflector 825083 825083 10 825083 2 17 Ceramic Wire Nuts FE 009 34 FE 009 34 FE 009 34 18 Rack Stop 825072 825072 825072 19 Access Control Box Cover 825195 825195 825195 20 Access Panel Screws SC 053 38 SC 053 38 SC 053 38 21 LH Pivot 2 Position 825196 22 RH Pivot 2 Position 825199 23 LH Pivot 4 Position 825071 825071 825071 24 RH P...

Page 9: ...8V 1024 2 825331 Heater 208V 1036 2 825300 Heater 208V 1048 2 825538 Heater 240V 1024 2 825332 Heater 240V 1036 2 825301 Heater 240V 1048 2 825098 Heater Socket 2 825100 10 Main Switch 2 825126 10 Contactor 1048 2 825128 90 Voltage Regulator 2 825100 80 Cooling Fan 2 825150 90 Actuating Switch 2 ...