Vtronix
Using the mounting bracket base as a guide,
mark two mounting holes on the wall. Drill
two mounting holes. Place anchors (provided)
into the holes until flush with the hole.
Position bracket on the wall and insert the
wires from the heating and cooling equipment
through the wiring hole. Holding the bracket
and rear case in place on the wall, secure it to
the wall using mounting screws (provided).
Fig.2. Mounting bracket(optional) and rear case on wall.
For mounting thermostat directly on the wall
(optional), drill two mounting holes (4-5/16 inch
apart). Place anchors into the holes until flush
with the hole. Holding the rear case in place on
the wall, secure it to the wall using mounting
screws (provided) as Fig.3
Fig.3. Mounting thermostat directly on the wall
Color-coded 18-22 gauge wire is recommended for
wiring. All wiring must follow local electrical code.
Loosen the terminal screw on the thermostat, strip
the wire and connect the wire as shown in Fig. 4.
Firmly tighten terminal screw when finished.
Follow wiring diagram shown in Fig. 8.
Fig.4. Connect system wires to thermostat terminals
(strip 5/6 inch).
Install the front case, carefully inspect wiring as
per diagram before mounting thermostat.
Fig.6. Mount the thermostat on the rear case by
first placing the thermostat on the top tabs
and then pressing down on the bottom of
the thermostat to snap in place.
Fig. 7. Tighten the screw.
3
VTRONIX, LLC Po Box 267096, Weston, FL 33326
Copyright
©
2017 Vtronix Document no. 170064-110E (Rev.00)