background image

Vtronix

SET UP

WARNING

Failure to set up according to the application may damage the heating and cooling system.

Set up mode

Press and hold TEMP 

 ,  TEMP 

  and FAN buttons at the same time for 3 seconds, the display will show 

the existing set up as per Table 1. Note that all 3 buttons have to be pressed simultaneously.

Display

Steady

Flashing 

P1

Auto Fan Timer – 1 hour (default)

Auto Fan Timer – 3 hour

P2

Continuous Fan (default)

Cycled Fan

P3

°

F (default)

°

C

P4

Cycled Fan Standard

Cycled Fan Override (default)

P5

Low Set temp Limit 64 º F (default)

Low Set temp Limit 70 º F 

 (1)

P6

Hi Set temp Limit 85 º F (default)

Hi Set temp Limit 78 º F 

 (2)

P7

3 minute delay time (default)

1 minute delay time

Table 1.  Set up table.

       Note (1) For T200 manual changeover, applies in cool mode only.

                (2) For T200 manual changeover, applies in heat mode only.

Example 1

: The Display shows 

P2

 steady means the thermostat is set up for Continuous Fan operation.

Change the Set Up Parameters

a)

While in set up mode, press TEMP 

  or  TEMP 

  button to go to the required set up parameter.

b)

To change the set up as listed in Table 1, press FAN button.

c)

Repeat (a) & (b) for the next set up parameter. 

d)

Press Heat/Cool button to exit from the set up mode.

Note 

:

If POWER button is pressed before exiting from the set up mode (Section d above), the 
thermostat will exit without changing the setup parameters.

P4 setting applies only when P2 is set to Cycled Fan.

OPERATION

Power

Press POWER to turn on/off the equipment. The thermostat will operate to the set point stored in non 
volatile memory.

Heat/Cool (For Manual changeover only)

Pressing  the Heat/Cool button will show whether the thermostat is in Heat or Cool mode. To change the 
current mode, press the Heat/Cool button again while the LED display 

 

is flashing.

Cool Mode – LED display 

 will flash “CL” for 5 seconds.

Heat Mode – LED display 

 will flash “HT” for 5 seconds.

Note:

 This button shows status for Auto changeover model. Heat/Cool can not be changed.

Fan

Press FAN button to select the fan speed in the following sequence.
LED at  

  will show the status of the fan. 

5