
Congratulations
on purchasing your new VTech product.
Before using this product, please read
Important safety instructions
.
This manual has instructions on how to
set up and register your new sensor. For
instructions on sensor settings, see the
user’s manual that came with your telephone
base.
Before use
Install batteries to the
Contact Sensor
NOTES
Use 2 x AAA batteries. Alkaline batteries are
recommended. If you use other kind of batteries,
the performance of the sensor varies.
Do not mix old and new batteries. Do not
mix alkaline, standard (Carbon-Zinc) or
rechargeable (Ni-Cad, Ni-Mh, etc) batteries.
While you insert the batteries, make sure the
polarities are correct.
The batteries operate properly under the
temperature between 0°F (-18°C) and 130°F (55°C).
Press the latch button on the sensor to
open the battery compartment case.
Insert two AAA alkaline batteries into the
battery compartment.
Add and register a sensor
You need to register your new
VC7002A
Contact
Sensor to your
VC7151-102A/VC7151-202A/
VC7151-302A
telephone system.
To register a Contact Sensor on
VC7151-102A/VC7151-202A/VC7151-302A
telephone system:
1. Press and hold
/HANDSET LOCATOR
on
the telephone base for about 4 seconds until
the
IN USE
light turns on. The telephone
base shows
Registering... Please wait
.
2. Press and hold the pair button (
P
) on
the Contact Sensor, until the LED light
flashes red, to enter the registration mode.
The telephone base shows
Contact X
*
registered
and you hear a beep when the
registration process completes. The registration
process takes about 90 seconds to complete.
*
Contact X
refers to the sensor’s name.
X
refers to the system-assigned number of the
sensor.
•
•
•
•
1.
2.
VC7002A
Accessory
Wire-Free Contact Sensor
for use with
VC7151-102A/
VC7151-202A/
VC7151-302A
User’s manual
P
Replacing a sensor
If you have purchased this new
VC7002A
accessory sensor to replace an old sensor,
follow the instructions to deregister your
old sensor.
VC7151-102A/VC7151-202A/
VC7151-302A
telephone system can support
up to 30 sensors.
To replace a sensor, deregister the registered
sensor first, and then register this new
sensor to the telephone base.
To deregister a sensor on VC7151-102A/
VC7151-202A/VC7151-302A series:
1. Press
MENU
when the phone is not in use.
2. Enter the code
*33734#
to access the
DEREGISTER
menu.
3. Scroll to
Single sensor
, and then press
SELECT
.
4. Scroll to the sensor you want to
deregister, and then press
SELECT
.
5. Press
YES
to confirm the deregistration.
The telephone base shows
Contact X is
deregistered
and you hear a beep when the
deregistration process completes.
Check the sensor before use
1. Separate the sensor unit from the magnet
unit.
You will receive alerts at your telephone
base. Refer to the Installation guide or
User’s manual of your telephone base
for the sensor alerts.
2. Combine the sensor unit with the magnet
unit.
•
Test the sensor signal strength
You can mount the Contact Sensor on a
door, window, drawer, cupboard, jewelry box,
or any object that opens or closes.
Before mounting the sensor, make sure you test
if the location you install the sensor is in range
from your telephone base.
Use adhesive tape to hold the sensor
temporarily in place.
Mount the sensor to a higher position to
avoid obstacles or blockages. Depending
on surroundings and obstructing factors,
like walls or cabinets, the sensor may not
transmit to the telephone base properly.
1. Take the sensor unit and magnet unit to
the desired mounting location, and use
adhesive tape to hold them temporarily in
place at the object and the frame.
2. Enter the
Check signal
mode under the
Sensor setup
menu at your handset to
test the sensor signal strength.
3. Open the door, window, drawer, cupboard,
or jewelry box again and check whether a
good signal is received at your telephone
base.
NOTES
If
No signal
or
Weak signal
message is
displayed in
Check signal
mode, mode, or if
you do not receive an alert when you open the
door, move the telephone base closer to the
mounting location or move the sensor closer to
the telephone base.
Depending on surroundings and obstructing
factors, like walls or cabinets, the sensor may
not transmit to the base properly.
After testing the sensor signal strength, mark
the mounting location on the door, window,
drawer, cupboard, or jewelry box and its
respective frame. Then, remove the adhesive
tape and proceed to the mounting process.
•
•
•
•
Mount with tape
1. Attach mounting tape
C
onto the
rectangular area at the rear side of the
magnet unit,
2. Stick the magnet unit onto the door.
Mount with tape
You can choose one out of the four spacers
with suitable height, and then add it to the
magnet unit.
1. Push the spacer towards the magnet unit
until it securely clicks into place.
2. Attach mounting tape
C
onto the
rectangular area at the rear side of the
spacer.
3. Stick the magnet unit onto the door.
Mount the sensor
We recommend you mount the magnet unit
on a door, window, drawer, cupboard, or
jewelry box, and mount the sensor unit on its
respective frame.
You can use the spacers provided if there is
a difference in level between the door and
the frame. The spacer will help to align your
sensor to the correct height. You can also
use a spacer if the frame is too narrow or has
some decorative molding.
NOTES
You can mount the sensor unit with mounting
tape first, and then use screws later if you
decide to mount it at that location for long term.
Make sure the mounting surface is clean. A
textured surface or any imperfections to a
smooth surface can keep the mounting tape
from making a strong bond.
Align the magnet unit with sensor unit when
mounting.
The distance between the sensor unit and
magnet unit must be
less than 1 cm (0.4 inch)
.
•
•
•
•
cc
Without spacer
Mount the magnet unit
With spacer
> 1 cm
(0.4 inch)
> 1 cm
(0.4 inch)
> 1 cm
(0.4 inch)
< 1 cm
(0.4 inch)
What’s in the box
Your product package contains the following items. Save your sales receipt and original
packaging in the event warranty service is necessary.
Overview
Sensor overview
1 – Magnet unit
2 – Sensor unit
Sensor unit overview
1 – Latch button
Press to open the battery
compartment case.
2 – Back cover
3 – P (Pair) button
Press and hold to enter the registration
mode.
4 – LED light
Red for a second when the sensor is
powered on.
Flashes red when the sensor is in the
registration mode.
5 – Battery compartment case
•
•
•
•
P
P
P
P
Sensor unit
Magnet unit
Spacer for
sensor unit
(optional)
Double-sided
mounting tape C
Spacers for magnet
unit
(optional)
Large screw x 2
(for fixing the
spacer on the
frame; optional)
Small screw x 2
(for fixing sensor
unit’s back cover on
the spacer; optional)
Double-sided
mounting
tape A
Double-sided
mounting
tape B
NOTES
The door images in this installation guide are for
conceptual reference only.
•