Configuration File Parameter Guide
209
VSP726 Administrator and Provisioning Manual
tone Module: Tone Definition Settings
The Tone Definition settings configure data for various tones for the purpose of locali
z
ation.
The Audio Manager component uses the data from this model to populate the mcu on
bootup.
Each tone definition must be at least one element containing a string of 12 element
attributes separated by a space:
"<num of freq> <freq1> <amp1> <freq2> <amp2> <freq3> <amp3> <freq4> <amp4>
<on duration> <off duration> <repeat count>"
Where:
<num of freq>: 0-2
<freq1>: 0-65535
(Hz)
<amp1>: -30–6
(dB)
<freq2>: 0-65535
(Hz)
<amp2>: -30–6
(dB)
<freq3>: 0
(for future development—modifying attribute has no effect)
<amp3>: 0
(for future development—modifying attribute has no effect)
<freq4>: 0
(for future development—modifying attribute has no effect)
<amp4>: 0
(for future development—modifying attribute has no effect)
<on duration>: 0-65535
(milliseconds)
<off duration>: 0-65535
(milliseconds)
<repeat count>: 0-65535
All the tone definition settings are included in the general configuration file.
Setting:
tone.call_waiting_tone.num_of_elements
Description:
Sets the number of elements for the call waiting tone.
Values:
1–5
Default:
1
Setting:
tone.call_waiting_tone.element.1
Description:
Defines the call waiting tone element 1.
Values:
Tone element string
Default:
1 440 -22 0 0 0 0 0 0 500 0 1