9050 USER MANUAL
VPC
07/19/2022
For more information visit vpc.com
13
9025TR HANDLE ROTATION AND SIDE CHANGE
PART # 310 104 369
NOTE:
The 9050TR receiver handle requires approximately 90° of counter-
clockwise movement for engagement and 90° of clockwise travel for
disengagement of the ITA. This handle is removable and adjustable to
accommodate different mounting configuration needs and for transport
purposes.
TOOLS REQUIRED
3
/
32
Allen Wrench
ROTATION
1.
Remove the handle screw with a
3
/
32
Allen wrench.
2.
Remove the handle and reposition in 90˚ increments (
Figure A
).
3.
Replace the screw and tighten until the handle is secured tightly.
SWITCHING HANDLE SIDES
1.
Using the
3
/
32
Allen wrench, remove the handle screw and handle (
Figure B
).
2. Using the
3
/
32
Allen wrench, remove the screw and handle washer on the left side of
the receiver (
Figure B
).
3. Install the handle into the left side hole at the preferred 90
°
position (
Figure C
).
4. Replace the screw and handle washer into the cavity on right side of the receiver.
Figure A. 9050TR Receiver handle can be rotated in 90 de-
gree increments to support test station set up needs.
Figure B. Remove handle from standard right side.
Figure C. Install handle on left side.