VoxPower NEVO+1200S User & Installation Manual Download Page 1

NEVO+1200 Series 

 

INSTALLATION MANUAL 

_________________________________________________________________________________________________________________________________________________ 

 

PLEASE READ THIS INSTALLATION MANUAL CAREFULLY BEFORE INSTALLING 

THIS PRODUCT AND KEEP THIS MANUAL FOR FUTURE REFERENCE.

 

 

WARNINGS

 

HIGH VOLTAGE WARNING: 

Dangerous voltages are present within the power supply. Covers may only be removed 
by qualified personnel when the power supply has been disconnected from the mains 
supply voltage for more than 3 minutes. Covers must be replaced and all screws secured 
properly before reconnecting to the mains voltage. 

FUSING WARNING: 

To ensure continued protection against risk of fire fuses must be replaced with the same 
type and rating of fuse. Replacements should be carried out by qualified personnel only. 

 

SPECIFICATIONS

 

 

INPUT ELECTRICAL – NEVO+ 1200 

Parameter 

Details 

Min 

Max 

Units 

Input Voltage (5) 

Nominally 100Vrms to 240Vrms 

85 
120 

264 
370 

Vac 
Vdc 

AC Input Frequency 

 

47 

63 

Hz 

Power Rating 

 

 

1200 

Watts 

Input Current 

1200 watt output at 120Vrms 

 

12 

Amps 

Fusing Fast 

acting 

 

12 

Amps 

NOTES: 
1.

 

NEVO+ 1200 inputs can only be used with NEVO series output modules and must not be used for any other 
purpose. 

2.

 

Use only a power source of the type indicated on the product label for the NEVO+ 1200 inputs.  

3.

 

For installation relating to UL60601-1 (Medical) a suitable fuse as described above must be provided in line with 
the Neutral inlet. 

4.

 

The NEVO+1200 input module is supplied with two integrated fans. Ensure that the inlet and outlet ventilation 
holes are not obstructed. Ensure there is adequate ventilation provided in the enclosure wherein or near which 
the power supply is mounted. 

5.

 

For Cases where compliance to various safety specifications (UL, CSA, EN) are required, to be described as 100-
240VAC, 50-60Hz nominal. 

 

 

 

 

 

OUTPUT ELECTRICAL 

Output  

Vmin 

Vnom 

Vmax 

Imax 

Pmax 

Ppk 

1.5V 5V  7.5V 25A  125W 

187.5W(4) 

4.5V 

12V 

15V 

15A 

150W 

225W(4) 

3 9V 

24V 

30V 

7.5A 

150W 

225W(4) 

18V 

48V 

58V 

3.75A 

150W 

225W(4) 

5 (Dual) 

5V 

12V 

15V 

5A 

75W (x2) 

75W (x2) 

6 (Dual) 

1.8V 

3.3V 

5V 

5A 

25W (x2) 

25W (x2) 

7 (Dual) 

1.8V/5V 

3.3V/12V 

5V/15V 

5A 

25W/75W 

25W/75W 

NOTES: 

1.

 

NEVO output modules can only be used with NEVO600, NEVO+600 and NEVO+1200 input modules and must not 
be used for any other purpose. 

2.

 

Take care when removing from or adding output modules to the NEVO+600 input so that components are not 
damaged in the process. 

3.

 

When the output voltage is adjusted upwards, the output current must be decreased proportionally so that the 
unit does not exceed the Pmax average power rating as stated in the table above.  

4.

 

Peak power up to Ppk is available for not more than 5 seconds at a maximum of 50% duty cycle. The maximum 
rated average power must not be exceeded.  Please refer to the full datasheet and user manual for more 
information on using the Ppk feature. 

 

 

 

 

 

 

 

ENVIRONMENTAL

 

 

Parameter 

Details 

Min 

Max 

Units 

Storage 

Temperature  

-40 

85 

°C 

Humidity 

Relative, non condensing 

95 

Altitude  

-200  5000 Metres 

Air Pressure 

 

54 

106 

kPa 

Ope

ration 

Temperature 

Full Power 

-20 

50 

°C 

Derate input and all outputs at 2.5% / °C 

50 

70 

°C 

Humidity 

Relative, non condensing 

95 

Altitude  

-200  3000 Meters 

Air Pressure 

 

78 

106 

kPa 

Noise Level 

Unit at idle 
Unit at full power,25°C 

Measured 1m from fan intake 

 42 

61 

 

dBA 
dBA 

 

Shock 

3000 bumps at 10G (16ms) half sine wave 

Vibration 

1.5G, 10 to 200Hz sine wave, 20G for 15min in 3 axes 

 

 

 

SAFETY

 

Parameter 

Details 

Min 

Max 

Units 

Isolation 
Voltage 

Input to Output 

 

4000 

Vac 

Input to Chassis 

 

1500 

Vac 

Output to Chassis 

 

250 

Vdc 

Output to Output 

 

250 

Vdc 

Isolation 
Clearance 

Primary to Secondary(Reinforced) 

 

mm 

Primary to Chassis (Basic) 

2.5 

 

mm 

Isolation 
Creepage 

Primary to Secondary(Reinforced) 

12 

 

mm 

Primary to Chassis (Basic) 

 

mm 

Leakage 
Current 

Standard: 250Vac, 60Hz, 25 °C 

 

1500 

uA 

Medical: 250Vac, 60Hz, 25 °C 

 

300 

uA 

 

 

 

 

 

GENERAL INSTALLATION 

Parameter 

Details 

Parameter 

Details 

Equipment class 

Flammability rating 

94V-2 

Installation category 

II 

IP Rating 

IP 10 

Pollution degree 

RoHS Compliance 

Yes 

Material group 

IIIb (indoor use only) 

 

 

 

 

 

 

MECHANICAL 

Parameter 

Details 

Size 

154.5mm (L) x 152.4 mm (W) x 41.0mm (H) 
(see diagram for tolerance details) 

Weight 

720 grams + 60 grams per output module 

Mounting 

Bottom mounting (See diagram details) 

 

 

IMPORTANT INSTALLATION NOTES 

 

This power supply is intended for use within equipment or enclosures which restricts access to authorised 
personnel only. The instructions in this manual and all warning labels on the product must be followed carefully. 

SAFETY

 

The NEVO+ 1200S is designed in accordance with safety requirements for UL 60950-1 2nd Ed. 2011-12-19, EN 
60950-1: 2006 + A1: 2010 + A11: 2009 + A12: 2011, IEC 60950-1: 2005 2nd Ed. Amd. 1: 2009, CSA C22.2 No. 60950-
1-07 + A1: 2011and LV Directive 2011/65/EU. 

The NEVO+ 1200M is designed in accordance with safety requirements for ANSI/AAMI ES 60601-1: 2005, EN 
60601-1: 2006, IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2, CSA C22.2 No. 60601-1-08 and LV Directive LVD 
2011/65/EU. 

All power supplies must be installed correctly in a controlled environment which restricts access to any 
unauthorised personnel. Equipment and system manufacturers must protect service personnel against 
unintentional contact with the output terminals. 

DERATINGS

 

Temperature - Input and output power must be derated by 2.5%/°C above 50°C. 

Input Voltage - Input and output power must be derated by 10W / Vrms below 120Vrms (1200W @ 120Vrms, 
1000W @ 100Vrms, 900W @ 90Vrms) 

Always remember to take the appropriate deratings into consideration before specifying any power supply for an 
application. If in doubt contact Vox Power. 

HAZZARDS

 

If series and/or parallel combinations of outputs exceed safe voltage and/or energy levels, the final equipment 
manufacturer must provide appropriate protection for both users and service personnel. 

HEALTH AND SAFETY  

To comply with section 6 of the health and safety at work act, a label that is clearly visible to service personnel 
must be placed on the final equipment, which warns that surfaces of the power supply may be hot and should not 
be touched when the product is operating.  

FUSING

 

The power supply has internal single pole fusing in the L (Live) line.

 

  

SERVICING

 

The power supply contains no user serviceable parts. Repairs must be carried out by authorised personnel only. 
Contact Vox Power Ltd for further information. 

APPROVAL LIMITATIONS – NORTH AMERICA 

When this product is used with 180VAC–253VAC mains where no neutral is present, connect the two live wires to 
L (Live) and N (Neutral) on the input connector. 

COOLING

 

For proper cooling of the power supply, the air intake and outlet must not be impeded. Allow 50mm clearance at 
both ends and position cabling appropriately.  

EARTH TERMINAL MARKING 

To comply with the requirements of UL60950-1, EN60950-1, IEC60950-1, CSA22.2 no. 60950-1, UL60601-1, 
EN60601-1, EN61010-1, IEC60601-1, IEC61010-1, CSA22.2 no 601-1 where the incoming wiring earth is intended 
for connection as the main protective earthing conductor and where the terminals for such a connection is not 
supplied on a component or subassembly such as a terminal block, the user shall add an appropriate label 
displaying a protective earth symbol in accordance with 60417-2-IEC-5019 directly adjacent to the terminal. The 
label should be durable and legible and should withstand the 15s rub test as per UL60950-1 section 1.7.15. 

WARRANTY

 

Contact your sales agent or Vox Power for product repairs. See Vox Power standard terms and conditions for 
warranty conditions. Vox Power products are not intended for use in connection with life support systems, human 
implantations, nuclear facilities or systems, aircraft, spacecraft, military or naval missile, ground support or control 
equipment used for the purpose of guidance navigation or direction of any aircraft, spacecraft or military or naval 
missile or any other application where product failure could lead to loss of life or catastrophic property damage. 
The user will hold Vox Power harmless from any loss, cost or damage resulting from its breach of these provisions. 

PRODUCT LABELS 

NEVO+ 1200M and NEVO+ 1200S 

The external product label contains information relevant to the power system. The label contains input voltage, 
maximum input current, input frequency, maximum output power, fuse rating and type, serial number, approvals 
and product part number in format NEVO+1200x-abcdefgh-zzzz. 

NEVO OUTPUT MODULES 

Each output module label contains information relevant to that particular output. The label contains voltage 
adjustment range, maximum output current, serial number, approvals and part number in format OPX. 

OTHER

 

 

A label warning that external surfaces are hot during operation and that the unit should be allowed to 
cool down properly should be placed on the unit where such a label is clearly visible. 

 

The NEVO+1200 range is designed to comply with EMC standards but it does not imply that the end 
system will comply.  

 

To prolong the life of the unit use in dust free environment. 

 

Units can be damaged during transit. Contact your sales agent or Vox Power and DO NOT apply power 
to the unit in case of transit damage 

 

Always use adequately sized cables and ensure good crimp connections. Use cable supports to 
minimise stress on connectors. 

 

Avoid excessive shock or vibration.

 

 

 

All specifications are believed to be correct at time of publishing. Vox Power Ltd reserves the right to make changes to any of its products 
and to change or improve any part of the specification, electrical or mechanical design or manufacturing process without notice.  Vox 
Power Ltd does not assume any liability arising out of the use or application of any of its products and of any information to the maximum 
extent permitted by law. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this 
document or by any products of Vox Power Ltd.  VOX POWER LTD DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND 
WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF SUITABILITY, FITNESS FOR PURPOSE, 
MERCHANTABILITY AND NONINFRINGEMENT.  
 
Please consult your local distributor or Vox Power directly to ensure that you have the latest revision before using the product and refer to 
the latest relevant user manual for further information relating to the use of the product. 

Vox Power Ltd products are not intended for use 

in connection with life support systems, human implantations, nuclear facilities or systems, aircraft, spacecraft, military or naval missile, 
ground support or control equipment used for the purpose of guidance navigation or direction of any aircraft, spacecraft or military or 
naval missile or any other application where product failure could lead to loss of life or catastrophic property damage. The user will hold 
Vox Power Ltd harmless from any loss, cost or damage resulting from its breach of these provisions.  

 

Vox Power Limited | Unit 2, Red Cow Interchange Estate, Ballymount, Dublin 22, D22 Y8H2, Ireland 

T +353 1 4591161 | www.vox-power.com

 

 

 