VOTRONIC Switch Unit 40 works on basis of a bistable relay allowing very high capacities combined with a very low own 

consumption. It suits especially as a remote-controlled main switch or load relay which is on long-term power. The 

current carrying capacity conducts 40 A.  

 

Switch Unit 40 can be mote-controlled 

by a normal switch

 (1 pol. ON / OFF).  

Furthermore the consumer can be switched on and off through an emergency switch at the relay by hand.  

 

 

The ranges of application are campers, intervention vehicles and boats: 

 

 

Easy selection through ON / OFF switch 

 

High switching current 40 A, short time to 60 A loadable 

 

Applicable as battery main switch through ON / OFF switch (remote-controlled)

 

 

Switching state monitor is visible from the outside  

 

Electronical delay prevent fast reactions like voltage drop or using strong consumer 

 

Suitable for long-term usage due to a very low consumption of the Switch Unit (compliant EN13976)  

 

No own electricity consumption if switched off with an external switch (remote-control)  

 

Automatical disconnection by under voltage 8.5 V (minimum operating voltage of Switch Unit 40)  

 

 

Switch Unit 40 cannot be used as a safety relay (emergency switch) to switch off dangerous 

machines or engines. Please check safety regulations!  

 

 

Please read this operating and installation manual thoroughly prior to connection and  

start-up. 

 

 

 

Installation: 

 

 

1.

 

Chose an installation place being cleaned and being protected from humidity and dust. 

2.

 

The installation place of the unit should be chosen in such a way, that the cables of battery and consumers can 

be as short as possible (losses) and that the pushbutton "EMERGENCY" is easily accessible. The unit should 

never be covered by any objects. 

3.

 

The switch unit is fastened solidly with screws in the casing flanges. The unit can be installed in any position. 

But please make sure that the connection terminals are easy to reach 

4.

 

Observe to fasten the connection cables in such a way, that neither high tensible force, nor high force of 

pressure is acting on the terminals. 

 

Connection: 

(Please regard the connection plan)

 

 

ALWAYS DISCONNECT THE POWER SUPPLY TO THE BATTERY PRIOR TO WORKING ON THE 

ELECTRIC SYSTEM TO AVOID SHORT-CIRCUITS! 

 

 

It is recommendable to use connection cables of different colours to avoid malfunctions due to mixed up connections.  

Observe: Only use red cables for plus "+" connection and black cables for minus "-" connection. 

 

The 2pol. screw terminal is connected correctly when cable lengths show to the right and the crews show up. 

The unit 

will not be damaged by eventual wrong polarization, but it will not be operating. 

Imperatively observe the cable cross 

sections and the polarity. Insert the fuses near the battery (safety for cable fire). 

 

 

 

 

Summary of Contents for Switch Unit 40

Page 1: ...r engines Please check safety regulations Please read this operating and installation manual thoroughly prior to connection and start up Installation 1 Chose an installation place being cleaned and being protected from humidity and dust 2 The installation place of the unit should be chosen in such a way that the cables of battery and consumers can be as short as possible losses and that the pushbu...

Page 2: ...roduct EMERGENCY towards OFF If the EMERGENCY lever is blocked due to dust dirt or hand blocking the electronic cannot work properly Application example Using as main switch Remote control through ON OFF switch in living room This application example enables through a switch in the living room the remote control of the product Current consumption of the unit is only 0 002 A therefore a miniature s...

Page 3: ...iodically for insulation faults points of break or loosened connections Occurring defects must be remedied immediately The unit is to be disconnected from any connection prior to execution of electrically welding or work on the electric system If the non commercial end user is not able to recognize the characteristic values being valid for a unit or the regulations to be observed a specialist is a...

Page 4: ...n of Conformity In accordance with the provisions of Directives 2014 35 EU 2014 30 EU 2009 19 EC this product complies with the following standards or normative documents EN55014 1 EN55022 B EN61000 6 1 EN61000 4 2 EN61000 4 3 EN61000 4 4 EN62368 1 EN50498 The product must not be disposed of in the household waste The product is RoHS compliant It complies with the directive 2011 65 EU for Reductio...

Reviews: