VOS-2FOM-D422T/R series

2-Channel Duplex RS-422 Data Transmission

Installation Manual

Fiber Optic Transmission Systems

VOSCOM TECHNOLOGIES CO.,LIMITED

WWW.VOSCOM.COM

TM

Summary of Contents for VOS-2FOM-D422MR

Page 1: ...VOS 2FOM D422T R series 2 Channel Duplex RS 422 Data Transmission Installation Manual Fiber Optic Transmission Systems VOSCOM TECHNOLOGIES CO LIMITED WWW VOSCOM COM TM...

Page 2: ...on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus 13 Refer all servicing to qualified service personnel Servicing is required when the appar...

Page 3: ...is also limited by fiber bandwidth Power adapter is manufactured by third party and is supplied with fitted screw terminal output cables Power adapter included for standalone US European UK or Austral...

Page 4: ...tion En_3 Installation Instructions NOTE1 Digital fiber optic transmitter and receiver should be used in pairs one is Transmitter LED is red the other is Receiver LED is green DC5V 1 2 3 4 DATA 3 POWE...

Page 5: ...Transmitter Rs422 2 Channel Duplex Rs422 Connection Input Output 4 Pin Terminal Block Pin Connect 1 CH Rs422 RX Connect 1 CH Rs422 RX Connect 1 CH Rs422 TX Output 1 2 3 4 DATA 1 2 3 4 Connect 1 CH Rs...

Page 6: ...m Receiver Rs422 2 Channel Duplex Rs422 Connection Input Output 4 Pin Terminal Block Pin Connect 1 CH Rs422 TX Connect 1 CH Rs422 TX Connect 1 CH Rs422 RX Input 1 2 3 4 DATA 1 2 3 4 Connect 1 CH Rs422...

Page 7: ...ktop or can be mounted to a wall VOS 2FOM D422T VOS 2FOM D422R NOTE Before mounting the transmitterand receiver please ensure that there is adequate space at both ends for viewing the front panel LEDs...

Page 8: ...LED indicator that illuminates when power is applied to the rack unit 5 Fiber optic plug in modules video cards can be installed into any of the available 14 slots of the card cage Most modules requi...

Page 9: ...rs and associated troubleshooting guidelines Table A Power Links Indicator Status Meaning Possible Cause Corrective Action Video LED VIDEO 1 VIDEO 2 Light Incoming video signal is present on thechanne...

Page 10: ...Data is not present on the channel No action required Data connection is faulty Check data connections Data communication cable is defective Replace cable The optical signal is not being received Rem...

Page 11: ...repair replacements nonwarranty repairs advance replacements and credit returns To obtain an RMA Download from www voscom com and please complete the RMA as much detail as possible then send the RMA t...

Page 12: ...repair department will evaluate the returned product to determine whether it is a warranty or non warranty replacement and bill you accordingly We will invoice advance replacements at shipment and cre...

Page 13: ...ut notice 2 You can download the latest PDF document here www voscom com 3 Online Technical Support please E mail support voscom com 4 More detail product information please E mail sales voscom com or...

Page 14: ...R MOISTURE DO NOT LOOK INTO OPTICAL PORTS WITH POWER ON Headquarters Information Distributor Information VOSCOM TECHNOLOGIES CO LIMITED Hangzhou Zhejiang P R CHINA 310004 Tel 86 571 87389389 Fax 86 57...