VOS-16010FDT/R series

16-Channel Video + 1 Duplex Data

Installation Manual

Fiber Optic Transmission Systems

TM

VOSCOM TECHNOLOGIES CO.,LIMITED

WWW.VOSCOM.COM

Summary of Contents for VOS-16010FDMR

Page 1: ...VOS 16010FDT R series 16 Channel Video 1 Duplex Data Installation Manual Fiber Optic Transmission Systems TM VOSCOM TECHNOLOGIES CO LIMITED WWW VOSCOM COM...

Page 2: ...on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus 13 Refer all servicing to qualified service personnel Servicing is required when the appar...

Page 3: ...imited by fiber bandwidth Power adapter is manufactured by third party and is supplied with fitted screw terminal output cables Power adapter included for standalone US European UK or Australian power...

Page 4: ...ata Rs485 B Conect Ground GND Input Output 1 2 3 3 FRONT PANEL FTX V1 DATA V2 V3 V4 V5 V6 V7 V8 1 2 3 V9 V10 V11 V12 V13 V14 V15 V16 ON OFF AC100V 240V EXT Installation Instructions NOTE1 Digital vide...

Page 5: ...Data Rs232 RXD Conect Data Rs232 TXD Conect Ground GND Receiver Rs232 One duplex Rs232 Data Connection Input Output 3 Pin Terminal Block Conect Data Rs232 RXD Conect Data Rs232 TXD Conect Ground GND I...

Page 6: ...ry terminated to 75 ohm unused BNCs should not be used for loop through video connections Typical Connection Panel Cable Connection En_5 DC5V 4A Power Supply Optic Output Optical Transmitter Monitor P...

Page 7: ...lone module the unit can be placed on a desktop or can be mounted to a wall NOTE Before mounting the VOS 16010FDT transmitter VOS 16010FDR receiver please ensure that there is adequate space at both e...

Page 8: ...ers a single slot opening 4 Each fiber optic plug in module is equipped with a POWER LED indicator that illuminates when power is applied to the rack unit 5 Fiber optic plug in modules video cards can...

Page 9: ...rs and associated troubleshooting guidelines Table A Power Links Indicator Status Meaning Possible Cause Corrective Action Video LED VIDEO 1 VIDEO 2 Light Incoming video signal is present on thechanne...

Page 10: ...Data is not present on the channel No action required Data connection is faulty Check data connections Data communication cable is defective Replace cable The optical signal is not being received Rem...

Page 11: ...repair replacements nonwarranty repairs advance replacements and credit returns To obtain an RMA Download from www voscom com and please complete the RMA as much detail as possible then send the RMA t...

Page 12: ...repair department will evaluate the returned product to determine whether it is a warranty or non warranty replacement and bill you accordingly We will invoice advance replacements at shipment and cre...

Page 13: ...ut notice 2 You can download the latest PDF document here www voscom com 3 Online Technical Support please E mail support voscom com 4 More detail product information please E mail sales voscom com or...

Page 14: ...R MOISTURE DO NOT LOOK INTO OPTICAL PORTS WITH POWER ON Headquarters Information Distributor Information VOSCOM TECHNOLOGIES CO LIMITED Hangzhou Zhejiang P R CHINA 310004 Tel 86 571 87389389 Fax 86 57...