Vortex Live Sinus 5/5BT Operating Instruction And Technical Description Download Page 15

AUTO mode: 
a) continuous auto-tuning to the resonance frequency (at the maximum current through 
the load), 
b) continuous auto-tuning of the specified current through the load; 
PRO mode: periodic auto-tuning of frequency and current after a user-defined time (30 
seconds by default); 
 
ENGINEERING mode: auto-tuning by frequency is disabled, by current-enabled by 
default; 
* dual-mode timer: 
a) countdown of the shutdown time (4 fixed values in offline mode, arbitrary-from an 
external application); 
b) periodic switching on after a specified time interval (available from an external 
application, including setting for Autonomous operation of the generator); 
• phase shift (voltage at the load relative to the current): any value in the range ±90° (in 
AUTO mode, the phase shift is not adjusted and by default is always 0°); 
* modulations of the main carrier frequency: 
* modulations of the main carrier frequency: 
AM-amplitude modulation: 
a) envelope shape: sine, meander, triangle; 
b) am depth: 0-100 %; 
C) envelope frequency: 0.1 Hz-1000 Hz; 
FM frequency modulation (swiping): 
a) modulating form: sine, meander, triangle; 
b) depth (range) FM: 0.1 kHz-1000 kHz; 
C) frequency (speed) FM: 0.1 Hz-1000 Hz 
AM and FM modulations are independent of each other and can be applied separately or 
simultaneously. 
* Communications: 
Bluetooth (ver. 2) - for communication with an external app on your smartphone 
(Android); 
USB-mini port - for communication with an external application on the PC and / or 
updating the firmware of the microcontroller; 
XLR plug (on the case) - for connecting the load; 
DS-025B (power socket on the panel) 2, 1x5, 5 mm-for connecting a power source; 
* Power supply: 12-24 V of stabilized or unstabilized DC voltage, recommended power 
supply voltage: 18-20 V; 
• Power consumed from the network, no more than: 12 W 
* Electrical class: Class II 
* Degree of protection: IP30 
* Weight and dimensions: 460 g, (l*W*h) 130x93x39 mm. 
* Operating conditions: ambient temperature from +5°C to +40°C, relative humidity up 
to 80% 

Summary of Contents for Live Sinus 5/5BT

Page 1: ...5BT kit You made the right choice We are sure that with its help You will be able to significantly improve your health and the health of your loved ones 1 Advantages of the Live Sinus device The Live...

Page 2: ...f the field color gray 4 indicator of the electrical component of the field green color 5 XLR USB cable for connecting coils in low voltage capacitive mode 6 boost adapter for connecting coils in high...

Page 3: ...turn on and control with just two buttons 1 connectors on the generator a XLR connector for connecting the load coils boost adapter first to the left b DC connector for connecting an external power s...

Page 4: ...t of generator settings gray button select the shutdown timer switch the waveform sine meander 3 LEDs indication of the selected timer additionally color indication of one of the three fixed values of...

Page 5: ...the XLR cable connector plug to the appropriate connector at the alternator b the USB connector from the opposite end of the cable into the USB connector coil 4 Connection of coils in high voltage mod...

Page 6: ...unds and the LEDs on the generator panel begin to flash synchronously and frequently indicating the process of searching for the resonant frequency and measuring the q factor of the connected coil Suc...

Page 7: ...hed in a circle 15 min 30 min 45 min constantly 15 min etc The timer value is indicated by the glow of the corresponding led on the front panel of the generator Timer mode constantly synchronously 1 H...

Page 8: ...f the available three and usually unused LEDs The change of steps is accompanied by a short beep unless the sound is disabled in the generator settings In the Live Sinus program the corresponding fiel...

Page 9: ...tically at the end of the set timer when the generator does not find lose the resonance frequency for example when the electrical connection is broken or when the electrical quality of the connected c...

Page 10: ...voltage mode The intensity of the indicator also depends on the power level set on the generator To check the field above the coil in this mode we recommend using a different indicator the indicator...

Page 11: ...monitor on which all parameters of the generator coil and signal can be monitored b allows you to directly control the operation of the generator i e it becomes an external control panel The current v...

Page 12: ...osed shape metal springs in the mattress bracelets chains etc Metal absorbs the field of the coil and dramatically reduces its effectiveness Metal implants in the body usually have a small area and re...

Page 13: ...ency and patience are important Some problems go away in 1 2 sessions while others may require months of persistent work As a rule the older slagged and sick a person is the stronger the body s reacti...

Page 14: ...ly green and yellow color display panel of the generator For high voltage modes when the parasitic electromagnetic component of the field is almost at the noise level you can safely use large power le...

Page 15: ...arrier frequency AM amplitude modulation a envelope shape sine meander triangle b am depth 0 100 C envelope frequency 0 1 Hz 1000 Hz FM frequency modulation swiping a modulating form sine meander tria...

Page 16: ...the device immediately and contact the seller from whom the device was purchased or directly to the manufacturer 14 Set composition N0 Name Quantity 1 Generator Live Sinus 5 2 Generator Sinus 5BT Live...

Page 17: ...ufacturer s warranty for all components of the kit is 1 year from the date of sale The manufacturer reserves the right to make changes to the design of the product that do not impair its consumer prop...

Reviews: