IR610 high performance vector control frequency inverter user manual Chapter3 Product appearance and wiring
- 19-
SIZE
Appearance and installation dimension
(
mm
)
A
B
B2
H
H1
H2
W
D
Φd
Mounting
screws
280KW-315KW
450
1045
1495
1075
1005
1560
550
450
Ø13.0
M12X30
Flooring mounting:H2*W*D=1560*550*450
355KW-400KW
630
1013
1425
1045
970
1495
730
450
Ø13
M12×30
Flooring mounting:H2*W*D=1495*730*450
450KW-500KW
660
1063
1505
1095
1020
1575
785
450
Ø13
M12×30
Flooring mounting:H2*W*D=1575*785*450
560KW-710KW
Only for Flooring mounting:H2*W*D=1800x1080x500
M12×30
3.1.3
Removal and installation of cover and inlet plate
SIZEA
~
SIZE C( 0.75KW-15KW) Removal and installation of cover and inlet plate
:
Removal steps
Step 1: Open the top cover
①
Unscrew the screw on the cover
②
Lift up the cover
③
Remove the cover from the front
Step 2: Take out the inlet board
①
Hold down the sides of the inlet plate with your
thumb and middle finger
②
Press to disengage the buckle and pull it out of the
board
Installation steps