Chapter 7 Selection guide of inverter Accessory IR610 high performance vector control frequency inverter user manual
- 160 -
5
PLC
Digital input power terminal
It is used for switching between high and low level
of switch input. It is short-circuited with +24V at the
factory, that is, DI is active at low level.
When the external power is input, disconnect the
PLC from the +24V.
It is a separate network from the PLC on the IO
board and is used separately.
7
PT
Support
PT100/PT1000/KTY84-130
AI4 is inactive when using
the
temperature
sensor
direct connection function
(temperature
detection
connection PT and COM)
ON
OFF
SW1
ON
OFF
SW2
ON
OFF
SW3
DIP switch switching mode:
DIP
switch
SW
1
SW
2
SW
3
AI4
ON
ON
ON
PT100
OFF
OFF OFF
PT1000
OFF
OFF
ON
KTY84-1
30
OFF
ON
ON
8
DI9
Digital input 9
Input frequency:
0~200Hz
Voltage
range:
0~30V
9
DI7
Digital input 7
11
AI3
Analog input 3 input 0~10V
12
DO6
Open collector output 6
Voltage range:
0~24V