- 135-
0- ACCEL/DECEL time 1
1- ACCEL/DECEL time 2
2- ACCEL/DECEL time 3
3- ACCEL/DECEL time 4
P42.24
PLC step 9-12
ACCEL/DECEL
time selector
Unit’digit: ACCEL/DECEL time 9
ten’digit: ACCEL/DECEL time 10
Hundred’digit: ACCEL/DECEL time 11
Thousand’digit: ACCEL/DECEL time 12
0- ACCEL/DECEL time 1
1- ACCEL/DECEL time 2
2- ACCEL/DECEL time 3
3- ACCEL/DECEL time 4
0000
☆
P42.25
PLC step 13-16
ACCEL/DECEL
time selector
Unit’s Digit: ACCEL/DECEL time 13
Ten’Digit: ACCEL/DECEL time 14
Hundred’digit: ACCEL/DECEL time 15
Thousand’s digit: ACCEL/DECEL tim 16
0- ACCEL/DECEL time 1
1- ACCEL/DECEL time 2
2- ACCEL/DECEL time 3
3- ACCEL/DECEL time 4
0000
☆
P42.26
PLC stop
decelerating
time
0.01
~
60000s
Setting value decide by P03.16
P03.16 = 2, 0.00
~
600.00s;
P03.16 = 1, 0.0s
~
6000.0s;
P03.16 = 0, 0s
~
60000s
20.00s
☆
43 Group Programming delay-unit
r43.00
Delay unit
output status
It is used to view the current output status of
the delay unit.
Bit definition is used, Bit0~Bit3 respectively
indicate the output status of delay units 1~4,
0 means invalid, 1 means valid.
-
●
IR610 inverter built-in 4 delay unit. The delay unit can collect the status of 0 ~ 15 bits of all parameters that can be
viewed in the function code table, and finally output the delay unit status after delay processing and logic selection.
Can be used for DI / DO, comparator / logic unit output delay and other functions, but also as a virtual relay.