- 119-
1:warning
Bit13:current limit status:0-no;1-yes
Bit14:overvoltage stall
Adjustment
:0-no ;1-yes
Bit15:undervoltage stall
adjustment :0-no;1-yes
r27.11
Drives running
mode2
Bit0
~
1:current command
source:0-keypad;1-terminal ;2-communicatoi
n
Bit2
~
3:motor option:0-motor 1;1-motor 2
Bit4
~
5:current motor
control:0-VF;1-SVC;2-VC
Bit6
~
7:current running
mode:0-speed;1-torque;2-position
-
●
r27.13
Run time
monitoring
0
~
65535min
0min
●
r27.14
Accumulated
power on time
Unit:hour
-
●
r27.15
Accumulated
running time
Unit:hour
-
●
r27.18
Heat sink
temperature
Unit:0.1
℃
-
●
r27.19
Main frequency
Unit:0.01Hz
-
●
r27.20
Auxiliary
frequency
unit:0.01Hz
-
●
r27.21
UpDown offset
frequency
unit:0.01Hz
-
●
30 Group Modbus communication parameter
P30.00
Communication
type
0:Modbus;
1:Canopen
0
★
P30.01
Drive Address
1
~
247
Different slaves on the same network should
set different local addresses;
1
★