Name [ID]
Description
Dim.
Pantograph status [112]
Status of the Pantograph outage function.
□ Pantograph fault
Fault " E41-Pantograph outage (page 33)" occurred.
□ Pantograph warning
Warning " W39-Pantograph outage (page 30)" occurred.
□ Turning off CHARGE
The charging contactor switched off during a pantograph outage fault or warning.
□ Motor torque = 0
During the pantograph outage, the motor restricted the motor torque to zero.
□ Enabled
Pantograph functions are enabled.
□ Block warnings
Blocking of warning is enabled.
Pantograph voltage [113]
Voltage of the pantograph of trolley vehicle.
V
4.4.7 Ext. thermal protection
Group of parameters number [868]
Diagnostic group of quantities of the external thermal protection (ETP).
MENU \ DIAGNOSTICS \ FUNCTIONS \ EXT. THERMAL PROTECTION
Name [ID]
Description
Dim.
ETP
Temperature
[869]
Temperature of the ETP sensor. After exceeding the temperature defined in the
parameter ETP Warning [865] (page 105), the converter generates a warning. After
exceeding the temperature defined in the parameter ETP Fault [866] (page 105), the
converter generates the fault " E38-ETP temperature (page 33)".
°C
ETP
Current
[870]
Measuring current of the external thermal protection. By rule, it is selected as the
signal source of an analog input, AOUT1 to AOUT3.
mA
ETP
Voltage
[867]
Value of measured voltage drop on the ETP sensor.
V
Sensor
resistance
[871]
Resistance value of the ETP sensor.
By multiple sensors connected to a series, it represents the average resistance value
on one of them.
Ω
4.4.8 Differential
Group of parameters number [1243]
Quantities for torque differential diagnostics.
MENU \ DIAGNOSTICS \ FUNCTIONS \ DIFFERENTIAL
Name [ID]
Description
Dim.
Value difference [1244]
Difference between the values of Sig.1 Value [1249] (page 107) and Sig.2
Value [1240] (page 107).
Nm
Freq. setpoint correction
[1245]
Frequency setpoint correction caused by differential operation.
Hz
4.5 Converter state
Group of parameters number [761]
Quantities regarding the overall state of the converter and its components.
MENU \ DIAGNOSTICS \ CONVERTER STATE
Name [ID]
Description
Dim.
Voltage 24V [72]
DC control voltage of 24V. Option for the detection of the supply load caused by
the control inputs and outputs. Converter generates the fault " E16-Supply
overload (page 32)" when the voltage drops under 16 V.
Battery voltage [773]
Voltage of the battery that backs up the history logs in the converter.
V
Converter
operational
hours
[496]
Converter operational hours. Converter operation time when switched on
(RUN). This value can be reset by authorized technicians only.
h
MT
operational
hours [497]
Motor operational hours. Converter operation time. This value can be reset by
the command Reset the motor operation hours MT [1075] (page 45).
h
Converter state [76]
Status word of the converter.
□ Fault
Converter is in fault.
□ SW_Err_Pin
System, internal converter status.