Electric Power Transfer (EPT)

EPT2, EPT10,

& EPT10C

Installation Instructions

© Allegion 2019

Printed in U.S.A.

941071-00 Rev. 8/19-f

Customer Service

1-877-671-7011

www.allegion.com/us

A.  Frame Backbox

B.  Metal - #10-24 x 3/8” Flat Phillips Head Machine Screw (4)

  Wood - #10 x 3/4” Flat Phillips Head Wood Screw (4)

C.  EPT2 - Wire Connectors 12 Gauge Yellow (4) 

  EPT10 - Wire Connectors 18 Gauge Violet (20)

  EPT10C - Wire Connectors 18 Gauge Violet (20)

D.  EPT Assembly

E.  Metal - #10-24 x 3/4” Flat Phillips Head Machine Screw (8)

  Wood - #10 x 3/4” Flat Phillips Head Wood Screw (8)

F.  Door Backbox

G. Strain Relief 

Tools for Install

Read all Warnings Before Starting Installation!

D

A

F

C

G

EPT2 Shown

E

B

Door Leaf

Frame Leaf

EPT10

EPT10C

Note: Door backbox is
 beveled to match door 

EPT2

To ensure the maximum amount of 
travel in arm for cam lift hinges, install 
EPT so door side leaf is oriented with 
knuckle on top. 

Summary of Contents for EPT2

Page 1: ...auge Yellow 4 EPT10 Wire Connectors 18 Gauge Violet 20 EPT10C Wire Connectors 18 Gauge Violet 20 D EPT Assembly E Metal 10 24 x 3 4 Flat Phillips Head Machine Screw 8 Wood 10 x 3 4 Flat Phillips Head Wood Screw 8 F Door Backbox G Strain Relief Tools for Install Read all Warnings Before Starting Installation D A F C G EPT2 Shown E B Door Leaf Frame Leaf EPT10 EPT10C Note Door backbox is beveled to ...

Page 2: ...fications apply to a 1 3 4 thick door 0 180 opening with up to 5 butt hinges 0 180 opening with up to 3 4 offset pivots 0 130 opening with 5 1 2 butt hinges 0 110 opening with 6 butt hinges Electrical Ratings EPT2 Two 18AWG wires Max Rating 24VDC 5A or 120VAC NEC Class 3 EPT cannot be used for 1 1 2 offset pivots larger than 6 butt hinges pocket pivots swing clear hinges center hung door center pi...

Page 3: ...kout D Install strain relief Field Wiring Strain Relief Frame Door OR Door backbox bevel must match bevel on door Top View Backbox is required for fire wood doors Rear knockout must be used 5 Mount EPT Assembly 4 Connect Wires 6 Verify that door opens and closes properly without binding and that electrical components function Connectors Keep area under elbows free of connectors splices and field w...

Page 4: ...EINFORCEMENT 060 16 GA MINIMUM OF EPT IN FRAME MUST ALIGN WITH OF EPT IN DOOR 1 4 FRAME DOOR DOOR OR FRAME DOOR OR FRAME SIDE VIEW SIDE VIEW WHEN INSTALLED WOOD HOLES PREPARED DURING INSTALL METAL 10 24 TAPPED HOLE 12 PLCS OPEN 180 RECOMMENDED 6 BELOW UPPER HINGE METAL WOOD X 1 4 DEEP 1 DIA THRU TO WIRE CHANNEL 5 8 DIA Note This drawing is not to scale Template ...