*941118-00*
941118-00
1.
Prepare door for exit device. See exit device
instructions for holes and backset.
2.
Transfer center line from inside (exit device side)
of door to outside (control side) of door. Use
extra care if edge of door is beveled. Be sure
center line is parallel to edge of door.
3.
Locate and prepare all holes as indicated in
diagrams on other side.
4.
Install exit device.
5.
Make sure control cam is in position shown
in Figure 1.
6.
Install cylinder, if used, in control (Figure 2).
7.
Make sure control cylinder plate is correct for
desired function (NL or TL; Figure 3).
8.
Disconnect top vertical rod.
9.
Apply control and rub plate to door and
secure with screws (Figure 4).
10.
Place rod member on top vertical rod so rod
member finger faces door and curved side of
rod member finger faces down (Figure 5).
11.
Insert rod member finger into slot in door.
Reconnect top vertical rod.
12.
With top latch bolt extended, slide rod
member up rod so rod member finger
touches control cam.
13.
Tighten set screws in rod member with 1/8”
hex wrench.
14.
Test key, control, and exit device action.
Figure 1.
Control cam position.
Control
cam
Mortise cylinder
cam must be in
position shown with
key removed; if
necessary, remove
cam and install in
correct position
Figure 2.
Cylinder installation.
Mortise
cylinder
Figure 3.
Cylinder plate.
Figure 5.
Rod member position.
Rod
Rod member
Curved side of
rod member
finger faces down
Cylinder plate
NL
TL
To change
cylinder plate,
remove screw
and washer
1/4-20 x 7/8”
undercut flat
head screw
Countersunk
washer with
1/4-20 oval
head screw
1/4-20 x 3/8”
undercut
flat head screw
Rub plate
Figure 4.
Control and rub plate
application.
2227
2227-F
9827/9927
9827-F/9927-F
Surface Vertical Rod Device
Application Schedule
3327/3527
3327A/3527A
3327A-F/3527A-F
Control for Metal Door Applications
374-T & 374-T-BE
Installation Instructions
Customer Service
1-877-671-7011
www.allegion.com/us
© Allegion 2014
Printed in U.S.A.
941118-00 Rev. 01/14-b