Alarm List
The alarm list and ECU alarm are the two first windows
from the main menu.
From the main menu press the arrow up button once
to reach the alarm list and twice for the ECU alarm list.
In the remote panel: Press Alarm list button.
Alarm List (Alarmlist)
The alarm list is automatically displayed when a new
alarm is triggered and the main menu is active.
The alarm list is not activated while values, parameters
and alarm history are being reviewed.
At position (
7
) the number in parentheses shows in
which ECU the fault code is. (1=EMS J1939, 2=EMS
and Power module J1587)
The alarm list heading shows:
•
Number of active alarms (
1
)
•
Number of unacknowledged alarms (
2
)
•
Total number of alarms (
3
)
•
Number of pages (
4
).
Scroll between the alarms in the list with the enter
key.
Status of alarm
•
Unacknowledged alarms are marked with * (
5
)
•
Active alarms are indicated by a black background
(
6
)
•
Inactive alarms are displayed without a black
background (
7
)
Fault handling
47711740 05-2019 © AB VOLVO PENTA
37