VOLTWORKS VS-3000QBR User Manual Download Page 1

MODEL:  VS-3000QBR

M. WARRANTY

This  product  is  designed  using  the  most  modern  digital  technology  and  under  very 
strict  quality  control  and  testing  guidelines.  If,  however,  you  feel  this  product  is  not 
performing  as  it  should,  please  contact  us: 

[email protected]

  We  will  do  our 

best to resolve your concerns. If the product needs repair or replacement, make sure 
to keep your receipt/invoice, as that will need to be sent back along with the package 
and prepaid to VOLTWORKS. 

The following situations will void warranty:

1. The box is distorted, damaged or changed, and interior parts damaged because of 

an exterior hit or drop not reported at time of delivery.

2. Connect the DC power incorrectly reversing the polarity. 

3. Dismantled or repaired the unit by an unauthorized person.

4. The unit was damaged by incorrect installation or operating method.

   

 To find out where to buy any of our products, you may also e-mail: 

Customer Service Contact:  [email protected]

V0.20.12

Warning: 

This manual contains important safety and

operating instruction. Please read it carefully before 
use

ing.

If the inverter still doesn't work after trying above measures, there may 
be some faults in the circuit. Please return it to the supplier for 
maintenance.

L. FAILURE GUIDELINES

No output voltage, 
buzzer sounds 
continuously

Incorrect output 
voltage

Cannot drive the 
load

1. Do not use when the battery is charging. 
2. Check the rated voltage of the battery 
and make sure that it is in the allowable 
range of the input voltage.

1. Turn on the power switch.
2. Check the cables and make sure they 
are tightly connected.

1. Use a true RMS multimeter to measure, 
such as model FLUKE 177/179.
2. Try to maintain the input voltage in the 
range of rated power
3. Change the battery of multimeter  then 
 test  again.

Reduce the load power, or turn on the 
appliance first, then turn on the inverter.

1. The switch is off.
2. The battery lead 
isn't connected well

1. RMS Multimeter 
measurement  error
2. The battery power 
of RMS Multimeter 
is low.
3. The input voltage 
is too high or too low.

1. Load power is too 
large, or the actual 
power of the 
appliance exceeds 
nominal power.
2. The starting power 
is larger than rated 
power (such as 
motor).

The internal inverter soft-start circuit will 
buffer starting the appliance.

Cut off the load and let it cool naturally for 
10 to 30 minutes. Restart it after it resumes 
to normal temperature. The load power is 
too large, reduce the total load power to the 
range of rated power. Avoid blocking the 
vent and improve the ventilation condition. 
Reduce the ambient temperature.

No output voltage

Low input DC voltage

High input DC 
voltage

Overload

 

Over temperature

 

Recharge or replace the battery

 

Reduce the load power.

 

Reviews: