Atom Series Quick Guide
V.1.0
Product Introduction
1
Front View:
Back View:
Product Overview
2
Atom is a compact unit which combines both benefits of UPS and inverter for long-time
operation. With built-in voltage stabilizer, it works as a UPS to accept wide input
voltage range and convert to stable and pure power source to the connected devices.
Besides, it also can provide stable power to a various of electronic devices from
personal computers, energy saving bulbs, television, to small inductive devices
such as fans. It is perfect choice for home owners or small office users in the unstable
power area.
1
2
3
4
Power switch
Line mode indicator: green lighting
Battery mode indicator: yellow flashing
Fault indicator: red lighting
1
2
3
4
AC input
Output receptacles
Circuit breaker
External battery terminal
2
3
1
4
Important Safety Warning
(
SAVE THESE INSTRUCTIONS)
3
Specifications
4
Model Atom 600
CAPACITY
INPUT
Voltage
Voltage Range
Frequency
OUTPUT
Output Voltage (Batt. mode)
Frequency Range (Batt. mode)
Transfer Time
Waveform
BATTERY
Battery Voltage
Maximum Charge Current
PHYSICAL
Dimension (DxWxH mm)
Net Weight (kgs)
ENVIRONMENT
Humidity
Temperature
600 VA / 300 W
12 VDC
13 A
230 VAC
140~300 VAC
50 Hz or 60 Hz
± 10%
50 Hz ± 1 Hz or 60 Hz ± 1 Hz
13 ms max.
Simulated Sine Wave
0-90 %
0-40 C (non-condensing)
358.5
X 96.8 X 146.5
5.8
2
4
1
Typical Amp. 1 meter (one-way) Dia-mm
Atom 600 50 A AWG 8 6.0
Table 1 Minimum Recommended Battery Cable Size versus Length
CAUTION!
The unit is designed for indoor use. Do not expose this unit to rain, snow
or liquids of any type.
CAUTION!
To reduce risk of injury, only use qualified batteries from qualified
distributors or manufacturers. Any unqualified batteries may cause damage and
injury. Do NOT use old or overdue batteries. Please check the battery type and date
code before installation to avoid damage and injury.
WARNING!
It's very important for system safety and efficient operation to use
appropriate external battery cable. To reduce risk of injury, external battery cables
should be UL certified and rated for 75 C or higher. And Do not use copper cables
less than 10AWG.
Personnel Precaution -
CAUTION!
Careful to reduce the risk or dropping a metal tool on the batteries. It could
spark or short circuit the batteries and could cause an explosion.
CAUTION!
Remove personal metal items such as rings, bracelets, necklaces, and
watches when working with batteries. Batteries can produce a short circuit current
high enough to make metal melt, and could cause severe burns.
CAUTION!
Avoid touching eyes while working near batteries.
CAUTION!
Have plenty of fresh water and soap nearby in case battery acid contacts
skin, clothing, or eyes.
CAUTION!
NEVER smoke or allow a spark or flame in vicinity of a battery.
CAUTION!
If a remote or automatic generator start system is used, disable the
automatic starting circuit or disconnect the generator to prevent accident during
servicing.
CAUTION!
Do not disassemble the inverter. Contact with the qualified service center
when service or repair is required.
WARNING!
Provide ventilation to outdoors from the battery compartment. The
battery enclosure should be designed to prevent accumulation and concentration
of hydrogen gas at the top of the compartment.
CAUTION!
Use insulated tools to reduce the chance of short-circuit when installing or
working with the inverter, the batteries, or other equipments attached to this unit.
CAUTION!
For battery installation and maintenance, read the battery manufacturer's
installation and maintenance instructions prior to operating.
3
India
Type Universal Type