48
Do not operate the multimeter when it is open, when the battery compartment is open, or the battery
compartment lid is missing. The safety mechanism prevents the opening of the battery and fuse lid
when test leads are plugged into the measurement sockets. It also prevents test leads from being
plugged in when the battery and fuse lid is open.
Measurements in damp rooms or under unfavourable environmental conditions are not permitted.
Unfavourable environmental conditions are: dampness or high humidity, dust and
fl
ammable gases,
vapours or solvents, as well as thunderstorms or similar conditions such as strong electrostatic
fi
elds,
etc.
Use only test leads or measurement accessories which meet the speci
fi
cations of the multimeter.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you use
the product for purposes other than those described above, the product may be damaged. In addition,
improper use can cause hazards such as short circuiting,
fi
re, electric shock etc. Read the instructions
carefully and keep them. Make this product available to third parties only together with its operating
instructions.
Observe all safety notes and information given in these instructions.
3. OPERATING ELEMENTS
See the fold-out page.
1 Rubber protective frame
2 Display
3 SHIFT/SETUP button
Switch the measuring function (red symbol on the rotary switch) /
switch function of the buttons (blue button labels)
4 Rotary switch for measurement function selection
5 mA
ȝ
A measurement socket
6 10 A measurement socket
7 °CHzV
measurement socket (for “plus” of the same size)
8 COM measurement socket (reference potential, “minus”)
9
-button
Low Imp. 400 k
button for impedance switching
125
Capacité
Plage
Précision
Résolution
60 nF
±(2,5 % + 20 digit)
0,001 nF
600 nF
±(2,0 % + 20 digit)
0,01 nF
6
ȝ
F
0,0001
ȝ
F
60
ȝ
F
0,001
ȝ
F
600
ȝ
F
0,01
ȝ
F
6000
ȝ
F
±(5 % + 20 digit)
0,1
ȝ
F
60 mF
non spéci
fi
é
0,001 mF
Protection contre la surcharge : 1000 V
Fréquence
Plage
Précision
Résolution
60 Hz
±(0,02 % + 8 digit)
0,001 Hz
600 Hz
0,01 Hz
6 kHz
0,0001 kHz
60 kHz
0,001 kHz
600 kHz
0,01 kHz
6 MHz
0,0001 MHz
60 MHz
0,001 MHz
Protection contre la surcharge : 1000 V ;
Pour 10 Hz – 60 MHz, amplitude d’entrée présente a : 1 Vrms
a
30 Vrms
Rapport cyclique (rapport impulsion-pauses)
Plage
Précision
Résolution
10 Hz – 2 kHz
(10 % – 90 %)
±(1,2 % + 30 digit)
0,01 %
Protection contre la surcharge : 1000 V