background image

4 Transportation and storage requirements

4.1 Product transportation requirements

Battery in the process of transportation should prevent violent vibration, impact
or extrusion, to prevent the sun and rain, can use cars, trains, ships, aircraft
and other means of transportation.
In the process of loading and unloading, the battery should be handled gently
to prevent throwing, rolling and weight.

4.2 Product storage requirements

Batteries should be stored in clean, dry and ventilated rooms where the
ambient temperature is -20

~ 60

and the relative humidity is no more than

85%.
Battery should avoid contact with corrosive substances, should be far away
from the source of fire and heat.
Battery storage SOC: 40% ~ 50%.
Long-term storage: before storage, the SOC should be more than 80%, and
the battery should be recharged every six months.The charging amount should
exceed 80% of the capacity

VOLTACON UK LIMITED

Energy Systems

Burnsall Road Industrial Estate

Coventry. CV5 6BU

United Kingdom

www.voltaconsolar.com  Email: [email protected]

Summary of Contents for ESS12100

Page 1: ...ESS12V100Ah LFP Battery User Manual Rechargeable Li ion Battery ESS12100 User Manual Information Version 1 0 20ESS SV0801...

Page 2: ...ions please contact Voltacon immediately for advice and clarification Content 1 Product introduction 1 1 1 Product features 1 1 2 Scope and purpose of application 1 2 Product parameters 2 2 1Battery m...

Page 3: ...reaches sustained 1C High safety lithium iron phosphate battery is safe and reliable High reliability interactive cooperative guarantee mechanism is adopted to improve system reliability Minimalist de...

Page 4: ...ue 1 Nominal capacity 100 Ah 2 Nominal voltage 12 8Vdc 3 Voltage range DC 10V 14 8V 4 Continuous charging current DC 50A 5 Continuous discharging current DC 100A 6 Working temperature 20 50 7 Humidity...

Page 5: ...l shut down If customers want to see the battery status please press the power button 1s again Long press the Power Button 3S to turn off the battery Self check lamp status When the initial self check...

Page 6: ...ALM SOC4 SOC3 SOC2 SOC1 Turn off All off Idle 0 25 All SOC Light is solid 26 50 51 75 76 10 0 Charge 0 25 The SOC top one is flashing oth ers are solid 26 50 51 75 76 10 0 discharg e 100 7 6 The Run l...

Page 7: ...ing Red light solid Red light flashing 2S flashing Red light flashing 4S flashing 2 3 System wiring 2 3 1 Parallel connection Before wiring the battery model make sure all batteries are turned off Fol...

Page 8: ...ve the same wire diameter and length This keeps the current flow of each battery consistent during operation 4 When 2 4 battery are connected in parallel the charge discharge current shall not exceed...

Page 9: ...goes into protective mode the whole system will shutdown 4 Each set of the battery external cables should have the same wire diameter and length This keeps the current flow of each battery consistent...

Page 10: ...e requirements Batteries should be stored in clean dry and ventilated rooms where the ambient temperature is 20 60 and the relative humidity is no more than 85 Battery should avoid contact with corros...

Reviews: