M
anual
F
ood
P
rocessing
e
quiPMent
O
peratOr
’
s
M
anual
4
r
ePlacing
the
B
lade
WARNING
Sharp Blade Hazard.
Blades are sharp and can cause cuts.
To avoid injury from sharp blades, handle with caution. Only trained
personal should operate equipment or perform maintenance.
Wash new parts with warm, soapy water and rinse thoroughly to remove the
thin protective oil film. Keep the sharp edge away from you when handling
blades.
To remove the blade cartridge and change the blade on EaziClean
®
models:
1. Move the handle (A) to the position as shown in Figure 9.
B
A
C
E
D
Figure 9. Blade Cartridge and Blade Removal and Installation.
2. Lift out the blade cartridge (B).
3. Note position or direction of the blade edge. Remove blade by loosening
screws (C).
4. Discard the old blade (E) and replace with new blade. Inspect the O-rings
(D) and replace if necessary.
5. Place the new blade (E) in the correct position. Secure with the
screws (C) and O-rings (D).
To change the blade on Premium
TM
models:
1. Move the handle (A) to the position shown in Figure 10.
2. Note position or direction of the blade edge. Remove the blade by
loosening screws (B).
3. Discard the old blade (C) and replace with new blade.
4. Place the new blade in the correct position. Secure with the screws (B).
A
B
D
C
Figure 10. Blade and Gear Removal and Installation.
r
ePlacing
the
g
ear
Wash new parts with warm, soapy water and rinse thoroughly to remove the
thin protective oil film.
To change the gear on EaziClean
®
models:
1. Use a tool to hold the old gear and turn the handle assembly in the
counterclockwise direction to unscrew the gear.
2. Discard the old gear.
3. If the blade cartridge was removed during gear removal it will be
necessary to align the collar (A) to the head (B). Rotate the groves
(C) so they align with ridges (D) and slide collar (A) into head (B). See
Figure 11.
B
A
C
D
Figure 11. Safe Operation Switch.
4. Move the handle (A) to the “UP” position. See Figure 10.
5. Slide the gear into position.
6. Use a tool to assure that the gear is held firmly. Lower the handle to the
“normal” position and rotate in the clockwise until tight.
7. Remove the tool.
To change the gear on Premium
TM
models:
1. Use a tool to hold the old gear and turn the handle assembly in the
counterclockwise direction to unscrew the gear.
2. Discard the old gear.
3. Move the handle (A) to the “UP” position. See Figure 10.
4. Slide the gear into position.
5. Use a tool to assure that the gear is held firmly. Lower the handle to the
“normal” position and rotate in the clockwise until tight
6. Remove the tool.