READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION.
PORTABLE ELECTRONIC PURIFIER
Page 1: ...READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION PORTABLE ELECTRONIC PURIFIER ...
Page 2: ...59 Technology ActivePure Electrical 12VDC or 110 240 VAC 50 60Hz with adapter Power Usage 12 Volts 10 7 Watts Max Conforms to UL STD 867 Mechanical Fuse 2 Amp Buss type 12VDC adapter only 3 Speed Fan Weight Dimensions 8 ounces 0 23 kg 3 625 W x 6 H x 1 0 D 9 21cm x 15 25cm x 2 54cm w o base Operating Temperature 45 F 100 F 7 C 38 C Recommended Maximum Coverage in a Contiguous Space1 Up to 50 sq ft...
Page 3: ...ug the unit before moving or cleaning or whenever the air cleaner is not in use DO NOT use outdoors or on wet surfaces DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit doing so will void your warranty Connect to properly grounded outlets only To reduce the risk of electrical shock do not change the plug in any way The unit must be disconnected from its power s...
Page 4: ...his device DIRECTIONS FOR USE Plug the cord into a working electrical outlet leaving at least one inch of open area to allow for airflow Please see owner s manual for detailed instructions on using handling storing and disposing of the device and procedures to mitigate any associated risks The use of this device is a supplement to and not a substitute for standard infection control practices users...
Page 5: ...50 FRESH AIR MOBILE SERV ACTIVEP TARGET F Red Wires UV BULB ACTIVEP C C C C A B D E A WIRE STAND B BASE C KNOB CLAMP PACK 2 D 12VDC ADAPTER E 2 0 AMP FUSE F AC ADAPTER Fuse for 12VDC Adapter only L O C K O P E N L O C K O P E N PU SH F ORDER PART 995015 FRESH AIR MOBILE SERVIC ACTIVEPUR TARGET FRA Red Wires UV BULB ACTIVEPUR C C A B D E Fuse for 12VDC Adapter only L O C K O P E N L O C K O P E N P...
Page 6: ... also be off the Purifier LED s will remain on DO NOT EXCEED RECOMMENDED SETTINGS PURIFIER O3 BOOST LOW LOW HIGH HIGH MED MED UP PURIFIER DOWN PURIFIER UP BOOST DOWN BOOST LEDs Setting Coverage Low Compact Car Pickup Med Large Sedan SUV or Semi Cab High RV Motor Home or Houseboat OFF Purifier off ionization fan may continue operating if desired CAUTION When running continuously for extended period...
Page 7: ...to accommodate several different mounting methods To reinstall simply align the two clamp collars and insert the wire stand Once the unit is adjusted tighten both knobs to hold it in place MOUNTING THE BASE The base for the Vollara FreshAir Mobile can be mounted using the included suction cups Velcro or screws depending on preference When using suction cups or Velcro be sure the surface is smooth ...
Page 8: ...he fuse is not blown test the unit using the supplied AC adapter Once the voltage problem drained car battery electrical system problem etc is corrected by a qualified service person you will be able to resume using your Vollara FreshAir Mobile with the 12 Volt DC adapter Sitting on a flat surface with or without the base Hanging over an edge pointing down laundry hamper garbage can etc Sitting on...
Page 9: ...r make sure the fit in the power outlet is snug A loose fit may can issues in unit operation or blown fuses THEN Insert the small adapter plug into the opening located underneath at the rear of the unit PRESS HERE Select and install the proper international plug into the AC adapter Insert correctly assembled adapter into a standard electrical outlet NOTE when installing one of the interchangeable ...
Page 10: ...bile will require periodic cleaning of certain internal components every one to three months ActivePure Target Clean the target by gently removing dust with a small soft brush UV Bulb The UV bulb should be gently wiped with a soft dry cloth Avoid handling the UV Bulb more than necessary ActivePure Ozone Plate The top area of the ActivePure Purification Plate can be cleaned with ammonia or alcohol ...
Page 11: ...the fuse is not blown check the outlet for proper voltage 2 UV bulb or O3 Boost may not be working Press the PURIFIER UP or PURIFIER DOWN buttons to turn the Purifier function ON If checking O3 Boost operation press the O3 Boost UP button to turn the O3 Boost ON Remove the Bulb Assembly clean and reinstall see diagram on Page 4 If cleaning and reinstalling does not correct the problem replace the ...
Page 12: ...58 ActivePure Bulb Assembly Service Kit 9950209 Base 9950154 Knob Clamp Pack 2 9950155 Wire Stand 9950153 To order replacement parts contact your Vollara Independent Business Owner or Customer Service for further assistance at 800 989 2299 or email customerservice vollara com REPLACEMENT PARTS SERVICE ...
Page 13: ... coverage prior to purchasing a product contact Vollara Customer Service at 800 989 2299 with the serial number located on the back of the unit EXCLUSION OF OTHER WARRANTIES AND CONDITIONS EXCEPT AS PROVIDED HEREIN AND TO THE EXTENT CONSISTENT WITH APPLICABLE LAWS WE MAKE NO REPRESENTATION OR WARRANTY OF ANY KIND ALL OTHER WARRANTIES OF ANY KIND EXPRESS OR IMPLIED ARE HEREBY EXPRESSLY DISCLAIMED I...
Page 14: ...his equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television which can be determined by turning the equipme...
Page 15: ...bled in P R C Vollara LLC All Rights Reserved For information regarding the use of this product please contact your Vollara Independent Business Owner or Customer Service at 800 989 2299 or email customerservice vollara com www vollara com FAM_OM_65 00817_VA 01561B_1121 ...