VOLKTEK NSH-5509 User Manual Download Page 1

 

 

Managed 8-port 10/100 Mbps  

plus 1-port 100-FX  

Access Switch

 

 

 
 
 

NSH-5509 

 
 

User Manual 

 

(December 2007) 

 

 
 
 
 
 
 

 

 

 

Summary of Contents for NSH-5509

Page 1: ...Managed 8 port 10 100 Mbps plus 1 port 100 FX Access Switch NSH 5509 User Manual December 2007...

Page 2: ...asonable protection against harmful interference in a commercial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the...

Page 3: ...allation 10 3 2 Mounting on a rack 10 3 3 Getting Connected 10 3 4 Powering On the Unit 11 3 5 Connecting Fiber Cable 11 3 6 Connecting Copper Cable 11 3 7 Connecting the Console Port Cable 11 3 8 Con...

Page 4: ...3 8 7 Port Mirroring 34 8 8 Trunk Configuration 34 8 8 1 Aggregator Setting 34 8 8 2 LACP Configuration 35 8 8 3 LACP Link Status 35 8 9 IGMP Menu 36 8 9 1 IGMP Configuration 36 8 9 2 IGMP Groups Stat...

Page 5: ...ions 52 10 TROUBLESHOOTING 53 11 APPENDIX A 54 11 1 RJ 45 Cables 54 11 2 Console Cable RJ 45 to DB 9 54 11 3 SNMP Trap List 55 12 APPENDIX B 56 12 1 Command Mode Summary 56 12 2 Command Summary User M...

Page 6: ...le lnet Http Web browser user interface CLI interface via console and te Xpress Ring redundant ring with less than 50ms recovery time per Ethernet ports 2km for multi mode and up to 120km for long hau...

Page 7: ...100BASE TX F IEEE 802 3x Flow C IEEE 802 3ad Port T IEEE 802 1d STP IEEE 802 1w RSTP IEEE 802 1p Priority Queu C 1 x 100Base FX SC ST 1 x RJ 45 Console Port Management Out of band mana In band manage...

Page 8: ...sio Dimensions ns 128 x 268 x 44 mm D x W x H The a J45 to DB9 pads One AC power cord optional adapter User Manual CD Safety EN 60950 Weight 1200g 1 6 Package Contents p ckage should include the follo...

Page 9: ...agers to remotely monitor the entire network s status quickly and easily via a network port or a console port out of band connection The Switch is designed with plug n play features for hassle free in...

Page 10: ...that delivers true plug n play capability just plug the network cables into the ports and the ports will adjust according to the end node devices The following cabling is recommended for the RJ 45 co...

Page 11: ...ach them to the underside of the Switch 3 Apply AC power to the Switch The green PWR LED on the front panel should light up 4 Connect cables from the network partner devices to the ports on the front...

Page 12: ...ng them gently with a clean tissue or cotton ball moistened with a little ethanol Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable and l...

Page 13: ...an use Ethernet cables to connect computers directly to the Switch ports You can also connect hubs switches to the switch ports by Ethernet cables You can use either crossover or straight through Ethe...

Page 14: ...PWR Off Primary power off or failure Flashing Green Indicating POST function upon start up POST On POST function successfully performed On Green Port operating at 100Mbps 100 1 st to 8 th Copper Ports...

Page 15: ...is necessary to activate the backup path For Xpress Ring any switch can be the arbiter just remember that the Arbiter Switch must be part of the ring Apart from rerouting the transmission within 50ms...

Page 16: ...also includes an embedded HTTP Web agent This Web agent can be accessed using a standard Web browser from any computer attached to the network The switch gives you the flexibility to access and manage...

Page 17: ...r such as Hyper Terminal attached to the console port The console port is set at the factory with the following default COM port properties Configure your own terminal to match the following Baud rate...

Page 18: ...provides CLI user interface via console or telnet After you log into the system the default privilege level is read only displayed with the prompt Username admin Password NSH 5509 3 Type enable and pr...

Page 19: ...r you enter write memory command the system will auto restart immediately NSH 5509 config exit NSH 5509 write memory It takes a few moments to write memory NSH 5509 write memory Restart system After t...

Page 20: ...e Switch s IP address then press Enter A Web Manager page like this will pop up on your screen Log in The default username is admin There is no preset password for this device so click on OK to procee...

Page 21: ...Gateway on System information page and click Apply to implement settings The system will notify you to save these settings with a pop on dialog box To save this configuration to flash memory click Sa...

Page 22: ...ting Modifies the name of the Switch Contact Location DHCP Client IP Address Subnet Mask Gateway Enter a contact name Enter the location of Switch Disabled or client s name Default 192 168 0 254 Defau...

Page 23: ...rom DHCP Server and you need to check the new IP address via the Serial Console If you change the setting of DHCP Client and click Apply the system will notify you to save the setting with a pop up di...

Page 24: ...onnections Type of connector for each port auto detects fiber or RJ 45 Enable or disable admin configurations Provides information on speed at which ports are currently operating Set speed for RJ 45 p...

Page 25: ...disable the Ethernet Loop Detection function of the Switch and enable or disable it on the specific port For MAC Address users can use the default one as the destination MAC address for Ethernet Loop...

Page 26: ...t devices in a network to ensure that only one route exists between any two stations and it provides redundant or backup links that automatically take over when a primary link goes down 8 4 1 Bridge C...

Page 27: ...l devices have the same priority the device with the lowest MAC address will then become the root device Set the interval between hello bridge protocol data units BPDUs sent by root switch configurati...

Page 28: ...ach port This will determine the route of information flow The higher the cost the less suitable the port is to be a node for the STP On the port is connected to an end node e g a network card install...

Page 29: ...though their physical location may be on a different segment of a LAN altogether VLANs are configured through software rather than hardware which make them extremely flexible Some of the advantages o...

Page 30: ...oyed using the Switch 8 5 1 VLAN Type VLAN Configuration The VLAN Type menu let users select the VLAN type of the Switch Parameter Description Disabled The VLAN function is disabled Port Based Tag Bas...

Page 31: ...configure the way in which each port treats the incoming frames that are marked for Tag based VLANs Parameter Description VID Priority Ingress Filter 1 Non Member and Filter 2 Untagged Set the VLAN ID...

Page 32: ...le tagged Disable The egress frames are not double tagged 8 5 4 Tag based Info VLAN Table The sub menu Tag based Info let users add modify or delete entries in the Tag based VLAN Table the configurati...

Page 33: ...d by other 802 1Q compliant devices for forwarding decisions The port is not participating in the VLAN as identified by the selected VID VLAN ID Click the Modify button to modify configurations of the...

Page 34: ...rate is 64Mbps Parameter Description Port Ingress Limit Mode Select to block the specified traffic from the port All Frames Restrict all kinds of packets Default exceeding the rate set in the Ingress...

Page 35: ...plement newly entered information or click Undo to restore previously saved configurations Parameter Description Mirroring Mode Select appropriate mode Disable Mirror mode is disabled Ingress Egress M...

Page 36: ...ore you configure trunk group check the setting of bridge function If bridge function has been enabled the system will display an error message when you click Apply Error Cannot save while Bridge Func...

Page 37: ...the routers is elected and assumes the responsibility of keeping track of group membership 8 9 1 IGMP Configuration This menu allows the user to Enable Disable IGMP Snooping and IGMP Query Port 1 9 I...

Page 38: ...ble the following configurations 8 10 1 MAC Table Status The user can view the MAC Table by selecting this function On this page the mark P means the MAC is learned from a downlink port and the mark T...

Page 39: ...Add the valid MAC address in the MAC field then select the priority and port number Press Apply to implement the input If you want to deny a host to access network via this switch type in the MAC addr...

Page 40: ...f users change the NIC of the PC or IP appliance the new MAC address will be learned in three minutes by the Switch within the set quantity limitations The MAC Limit Function can be disabled or enable...

Page 41: ...sessions share the same link Once you adjusted the basic settings use the Apply button to implement these changes 8 11 2 Tag Priority The user can define up to eight different priority values for the...

Page 42: ...r can see the serial port configuration that can be utilized while accessing the switch via Console port Click on each parameter field to modify the desired setting then click Apply to implement newly...

Page 43: ...This management method requires the SNMP agent on the switch and the SNMP Network Management Station to use the same community string This management method in fact uses two community strings the GET...

Page 44: ...an send alarm notifications via e mail to assigned e mail addresses in case of any abnormal events Up to 5 e mail addresses can be assigned Click on each parameter field to modify the desired setting...

Page 45: ...nformation or click on Undo to restore previously saved configurations Parameter Description User Name Password User Level Modify the default Username Modify the User Password Read Write Users with th...

Page 46: ...ddress fields are left blank or are not enabled the Switch s remote management interfaces will become deactivated until such an act is reversed by accessing the Switch at this page or via the console...

Page 47: ...600 seconds but if Block Port Permanently is enabled the Block Duration 600 seconds will not apply and the port will be blocked forever or until the manager unblocks it by accessing the Port Settings...

Page 48: ...the same configurations Backup settings Click the Backup Setting button and a download window for Config bin will appear Save the file in a safe location for later retrieval Restore settings Click on...

Page 49: ...the power Parameter Description System Restore Factory Default Settings System Reset Clicking on the Restore button will set the switch back to factory defaults All saved configurations will be lost C...

Page 50: ...r name and password The default log in name is admin with no preset password The user mode is the default login level for a valid user account After you log in type in or help followed by Enter key to...

Page 51: ...ration Show rate control configuration Show RMON information Show RSTP configuration Show SNMP configuration Show static unicast MAC configuration Show system configuration Show trunk configuration Sh...

Page 52: ...witch priority 9 3 3 Virtual LAN configurations Before you configure VLAN parameters you should setup the VLAN type to Tag Based For example use the following commands to setup tag based VLANs NSH 500...

Page 53: ...the network management systems as needed Type a question mark after snmp command to display a full list of help commands with explanations NSH 5009 config snmp contact Set system contact name getcommu...

Page 54: ...to resolve the problem replace the power supply unit Symptom Link indicator does not light up after making a connection Cause Network cable or fiber copper port is defective Solution Ensure that the...

Page 55: ...White Pin 5 N A Pair 1 White Blue Pin 6 RX Pair 3 Green White Pin 7 N A Pair 4 Brown White Pin 8 N A Pair 4 Brown White Application Cable Type Application Switch to Switch or Network Adapter Straight...

Page 56: ...CH RJ 45 8 pin to DB9 F pin assignment 11 3 SNMP Trap List 1 Switch Traps Group private z Cold start z Warm start z Link up z Link down z System configuration change 2 MIB II Traps z Cold start z Warm...

Page 57: ...vilege Command Description enable Turn on privileged commands exit Exit from current mode help Show available commands history Show a list of previously run commands logout Disconnect ping ip address...

Page 58: ...ion configuration cable all Show cable test results of all ports port Show cable test results of individual port hdos Show Host Denial of Service configuration email alarm Show email configuration fra...

Page 59: ...vlan table Show tag based VLAN VLAN table xpress Show Xpress Ring configuration write memory Save configuration 12 4 Command Summary Configuration Mode read write privilege Command Description exit E...

Page 60: ...alarm type gateway Set gateway igmp Set IGMP query mode auto enable disable Set IGMP query mode snooping enable disable Set IGMP snooping static port list Set IGMP static port interface port channel p...

Page 61: ...schedule all high before low weighted fair Set QoS schedule weighted fair ip enable port id enable disable Set QoS ip enable ip over tag port id enable disable Set QoS ip over tag ip tos pri 0 63 low...

Page 62: ...iguration vlan type disable Disable VLAN port base Enable port based VLAN 802 1q Enable 802 1q VLAN tag based VLAN xpress ring enable Enable Xpress Ring port 1 port id Set Xpress Ring port 1 port 2 po...

Page 63: ...limit action enable disable Enable Disable MAC limit for the port s quantity 1 20 Set MAC limit quantity for the port s mirror Enable port mirroring in the interface name Set a name for the port s no...

Page 64: ...mmands logout Disconnect ping ip address Ping a specified host with IP address manage This VLAN Group ID is a management VLAN member port list Specify the port s you don t want to modify all outgoing...

Page 65: ...5509 MANAGED 8 PORT 10 100 1 PORT 100 FX SWITCH 13 Contact Information VOLKTEK CORPORATION 4F No 192 Lian Cheng Road Chung Ho Taipei 235 Taiwan ROC TEL 886 2 8242 1000 FAX 886 2 8242 3333 ISO 9001 Ce...