– Press
←
button 3 times to go back to diagnosis function
menu.
Select diagnosis function “014-Long adaptation”.
– Select “Channel number 14”.
– Klick on
Keyboard
.
– Enter adaptation value “0001”.
– Press
→
button.
– Confirm value with
Confirm
button.
– Stop regeneration by pressing
Save
button.
The regeneration is cancelled and must be restarted as neces-
sary.
WARNING
Before restarting the regeneration, makes sure that the
hazard will not occur again.
3.9.4 Adapting ash deposit mass of diesel par-
ticulate filter, engine codes CPYA, CPYB,
CPYC, CPYD, CPYE
Note
◆
The ash deposit mass can only be adapted if the regenera-
tion of the diesel particulate filter has been performed be-
forehand. The adaptation must be performed after each re-
generation.
◆
By adapting the ash deposit mass, the calculated ash de-
posit mass in the engine control unit will be recalibrated.
◆
The ash deposit mass must be adapted right after the regen-
eration has been completed and without the ignition being
switched on and off.
– The engine is still running since the previously completed re-
generation.
– Select diagnosis function “015-Access permissions”.
– If available, select “015.2 Security Access (automatic)”.
– Enter following access code:
● Access code: 18711
– Confirm access code.
– Press
←
button 3 times to go back to diagnosis function
menu.
– Select diagnosis function “14-Long adaptation”.
– Select “Adaptation channel 17”.
– Klick on
Keyboard
.
– Enter adaptation value “0001”.
– Press
→
button.
3
Industriemotoren - Industrial Engines 2009
▶
Workshop Manual for Diesel Engine (2.0 l/36-75 kW_EA 189) 05.2015
458
Repair Group 26 - Exhaust system