BTS-Ex, non-contacting thermal switch unit
Installation
6.4 Mounting, connection - evaluator
NOTICE
Damage to property
Damage to the system by electric components not connected properly and/or not
complying with the mounting instructions.
•
Wiring of the BTS-Ex is not included in Voith's scope of supply!
•
In case of longer distances between initiator and evaluator, we recommend
using a shielded cable for extension purposes.
•
Total resistance of an extension cable between initiator and evaluator to be
less than 100
Ω
.
•
Install the evaluator into an appropriate cubicle and connect it in accordance with
the wiring diagram.
Wiring diagram:
Fig. 7
Evaluator
KFD2-SR2-Ex2.W.SM
Chapter 15.5
BN: brown BU: blue
24 V DC
*
)
*
)
LB = open circuit, LK = short-line fault