background image

 

 

                                                                                       

 

Dear Customer, 
If you follow the recommendations contained in this Instruction Manual, our 
appliance will give you constant high performance and will remain efficient 
for many years to come. 

 
Product Specification & Technical Parameters 
 

Model 

RH.600.WH

Rated Voltage 

2

3

0V 

Rated Power Frequency 

50Hz 

Light Power 

1

x25W 

Motor Power 

1

x120W 

Total Power 

145

Diameter of Outlet Adapter

1

2

0mm

Di

mension(mm)

 

W600 X D

48

0 XH

147

 

 
RECOMMENDATIONS AND SUGGESTIONS 
 

INSTALLATION 

* The manufacturer will not be held liable for any damages resulting from 
incorrect or improper installation. 
* Please read this instruction manual before installing and using this range 
hood.  Please  keep  this  instruction  manual  in  a  safe  place  for  future 
reference. 
* This range hood can be used either in the Ducted Mode (ducting fumes to 
the outside) or in the Recirculation Mode (internal recycling). The choice of 
modes can be left to the customers. 
* Only a qualified and trained service technician can undertake the work of 
installation and servicing. 
* Check that the main voltage corresponds to the one indicated on the rating 
plate fixed inside the hood. 
*  Do  not  connect  the  hood  to  exhaust  ducts  carrying  combustion  fumes 
(boilers, fireplaces, etc.) 
* If the hood is used in conjunction with non-electrical appliances (e. g. gas 

Summary of Contents for RH.600.WH

Page 1: ...our product please carefully read the following important information regarding installation safety and maintenance And Keep this information booklet accessible for further consultations RANGE HOOD INSTRUCTION MANUAL MODEL RH 600 WH ...

Page 2: ...correct or improper installation Please read this instruction manual before installing and using this range hood Please keep this instruction manual in a safe place for future reference This range hood can be used either in the Ducted Mode ducting fumes to the outside or in the Recirculation Mode internal recycling The choice of modes can be left to the customers Only a qualified and trained servi...

Page 3: ...han what it has been designed for Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the pan sides Deep fat fryer must be continuously monitored during use overheated oil can burst into flame The hood should not be used by children or persons not instructed in its correct u...

Page 4: ...e use or keep the appliance only under supervision of adults and out of the reach from children Don t use this product outdoors This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for...

Page 5: ... A straight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible Larger ducting may be required for best performance with longer duct runs 4 The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels Regulations concer...

Page 6: ...l Connection Electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards Turn off electrical power at service entrance before wiring If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not use the plug and an extension cord other than the ones initially ...

Page 7: ...for the various possibilities are indicated Proceed with fixing the hood Based on your requirements you can fit the hood on the wall or on a wall unit of your kitchen IMPORTANT Respect the distance between the hob and lower part of the hood which must be at least 650mm Fixing to the wall 1 Draw a line on the wall in vertical line with your hob Mark the 4 holes to be drilled in the wall respecting ...

Page 8: ...ded 2 Make the electrical connection Installation is now complete We recommend you CHECK THAT THE DUCTING RECIRCULATING LEVER IS IN THE RIGHT POSITION The lever is found on the motor unit and must be positioned on the symbol E in the case of installation in ducting version Also remember that the use of charcoal filter s is not necessary with the ducting version if these are fitted please remove th...

Page 9: ...witch turns the fan on to three speed settings MAINTENANCE GREASE FILTER The grease filters should be cleaned frequently every two months of operation or more frequently for heavy use Use a warm detergent solution Grease filters are washable LAMPS This range hood requires one normal lamps AC 230V 40W Max Note This manual covers several different models the information for each model may differ sli...

Reviews: