Specifica tions
WBV.PU.002.EN VX186QD V2.0
11
3
Specifications
VX186QD
series
Max. rotation speed:
600 min
-1
Max. differential
pressure**
Theoretical
torque***
Displacement
Theoretical volume
flow*
Size
[l]
[l/min]
[m
3
/h]
[bar]
[Nm]
92
3.57
2142
129
12
820
130
5.05
3030
182
12
1100
184
7.15
4290
257
12
1540
260
10.10
6060
364
10
1835
368
14.29
8574
514
8
2100
390
15.15
9090
545
7
1975
520
20.19
12114
727
6
2250
736
28.58
17148
1029
3
1680
*
All values refer to the theoretical volume flow. The actual volume flow is lower; it depends on the
operating conditions in each case.
**
Valid only for short operation times. For continuous operation, please contact our service department.
The service life of the lobes is reduced by high temperatures, especially in combination with high
pressure. Observe the material-specific differential pressure limits
Notice
.
***
Theoretical operating torque with max. differential pressure and water, designed for NBR elastomers.
ATTENTION
Speed reduction for highly viscous media
When using the pump for a highly viscous medium, the pump speed must be reduced according to the
material's viscosity, to prevent the intake flow from breaking off on the suction side (cavitation protection).
Material-specific differential pressure limits
With some materials, premature wear is likely if the pump pressure is too high. Observe the following
material-specific differential pressure limits.
FPM lobes:
max. 6 bar
Cartridge mechanical seal made of Duronit:
max. 10 bar
Maximum free passage: Ø 61 mm
Weights and dimensions
For the machine's weight and dimension specifications, see
"Dimension sheet"