Rotary lobe pump
Operating instructions
VX100Q, VX136Q..QD..QDM2, VX186Q..QD..QDM2, VX230Q..QD
42/68
8.2
Before opening the Q or QD cover
Before opening the Q and QD cover:
•
Depressurise the pump assembly.
•
Shut off the connected pipes.
•
Empty the pipe as much as possible using drain cocks.
Attention! The remaining liquid flows out of the pump when the cover is opened.
8.3
Opening the Q cover
Fig.
"Opening/Closing the Q cover"
1.
Depressurise buffer chamber (if rotary lobes are to be dismounted).
2.
Loosen hexagon nuts (1) (or hexagon head screws (1) on VX230 series) on the Q cover (5).
3.
Remove Q cover and remove the O-ring (6).
8.4
Closing the Q cover
Fig.
"Opening/Closing the Q cover"
1.
Thoroughly clean the contact surfaces before installing the Q cover (5).
2.
Pull the O-ring (6) onto the Q cover.
3.
Set the Q cover in place.
4.
Screw four hexagon nuts (1) onto the threaded rod and tighten, or on VX230 series attach the Q cover
with 8 hexagon head screws (1).
Attention! When doing so, ensure that you do not tilt the Q cover, evenly tighten by hand!
Ensure correct seating of the O-ring.
Fig.
23
: Opening/Closing the Q cover
1
Hexagon nut / Hexagon head screw
5
Q cover
6
O-ring
Summary of Contents for VX Series
Page 1: ...Best Practices for Installation of VX Rotary Lobe Pumps WELCOME TO VOGELSANG FACTORY TRAINING ...
Page 15: ...Installation ...
Page 24: ...Pressurizing the Pump ...
Page 36: ...Direction of flow Startup Checklist Startup ...
Page 44: ......
Page 121: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Page 122: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...
Page 123: ...Service Manual Service Manual Pump Models VX Series Q Pumps ...