![Vogelsang VX Series Manual Download Page 62](http://html.mh-extra.com/html/vogelsang/vx-series/vx-series_manual_1044344062.webp)
Rotary lobe pump
Operating instructions
VX100Q, VX136Q..QD..QDM2, VX186Q..QD..QDM2, VX230Q..QD
18/68
5.2
Pump and motor on base
Noise and vibration hazard
Wear
Noise, vibrations and oscillations can cause impairment of communication and discomfort.
To avoid wear, vibration and generation of noise:
•
the base for the pump and motor must not be tensioned during installation.
•
the
orientation of the coupling
must be checked and, if necessary, corrected before start-up
,
Fig.
"Orientation procedure".
Retighten all motor and pump mounting screws on the base
after 20 operating hours.
Fig.
12
: Orientation procedure
“Technical Information TINF.PU.020.xx, accompanying sheet for belt drives"
For pumps with belt drive check the belt tension acc. to the accompanying sheet:
•
At start up
•
before and after longer out-of-service periods
•
After the first 10 operating hours
•
every 2000 operating hours, once per year minimum
Chap.
“Maintenance plan"